IR Frequencies & Mixed Analytical Practice
Characteristic IR group frequencies mixed with general analytical statistics, calibration and electroanalysis.
Assessment Overview: 5 multiple-choice questions assessing conceptual and mathematical proficiency in IR Frequencies & Mixed Analytical Practice.
Practice Questions & Answers
Question 1: The CH3 of 1,1-dichloroethane appears as a
- A. singlet
- B. triplet
- C. doublet (Correct Answer)
- D. quartet
Pedagogical Explanation: With n = 1 equivalent neighbor(s), the n+1 rule gives 2 line(s): a doublet.
Question 2: Why is dichromate often chosen over permanganate as the oxidant?
- A. Is less toxic
- B. Is more intensely colored
- C. Reacts much faster
- D. Is a stable primary standard needing no standardization (Correct Answer)
Pedagogical Explanation: Potassium dichromate is stable in solution and as a solid, non-hygroscopic, and obtainable in high purity: it is a primary standard, while KMnO4 must be standardized.
Question 3: ISEs can serve as indicator electrodes in titrations, e.g.,
- A. redox only
- B. fluoride titrated with La³⁺, or chloride with Ag⁺ (Correct Answer)
- C. never
- D. acid-base only
Pedagogical Explanation: The ISE tracks the free ion through precipitation/complexation titrations, jumping at the endpoint.
Question 4: Replicate results (mg/L): 101, 98.2, 101.5, 99.1, 102.3. True value = 100.0 mg/L. These results are:
- A. Precise and accurate
- B. Neither precise nor accurate
- C. Precise but not accurate
- D. Accurate but not precise (Correct Answer)
Pedagogical Explanation: Mean = 100.42 mg/L vs true 100.0 (relative error 0.4%), RSD = 1.7%. Scattered replicates and mean close to true -> accurate but not precise.
Question 5: A calibration line is signal = 1.05 x conc + 0.29. A sample gives signal 11.42. Its concentration is:
- A. 10.9
- B. 10.6 (Correct Answer)
- C. 21.2
- D. 11.2
Pedagogical Explanation: conc = (signal - intercept)/slope = (11.42 - 0.29)/1.05 = 10.6.