Multi-Component Analysis and Applications
Isosbestic points, simultaneous equations, derivative methods, and real assays.
Assessment Overview: 5 multiple-choice questions assessing conceptual and mathematical proficiency in Multi-Component Analysis and Applications.
Practice Questions & Answers
Question 1: Two-component mixture (b = 1 cm). At λ₁: εX = 1.5e+04, εY = 8000; at λ₂: εX = 5000, εY = 1.6e+04 (L·mol⁻¹·cm⁻¹). Measured A₁ = 0.23, A₂ = 0.21. What is c(Y) in mol·L⁻¹?
- A. 1.312e-05
- B. 1e-05 (Correct Answer)
- C. 0.0001
- D. 2.875e-05
Pedagogical Explanation: Solve simultaneously: A₁ = εX₁bcX + εY₁bcY; A₂ = εX₂bcX + εY₂bcY. Solution gives c(Y) = 1e-05 mol·L⁻¹.
Question 2: Two-component mixture (b = 1 cm). At λ₁: εX = 1.8e+04, εY = 4000; at λ₂: εX = 5000, εY = 1.9e+04 (L·mol⁻¹·cm⁻¹). Measured A₁ = 0.22, A₂ = 0.24. What is c(X) in mol·L⁻¹?
- A. 1e-05 (Correct Answer)
- B. 0.00023
- C. 0.0001
- D. 1.222e-05
Pedagogical Explanation: Solve simultaneously: A₁ = εX₁bcX + εY₁bcY; A₂ = εX₂bcX + εY₂bcY. Solution gives c(X) = 1e-05 mol·L⁻¹.
Question 3: Activity: Maintaining the quality manual. This is:
- A. Both equally
- B. QA (Correct Answer)
- C. Neither
- D. QC
Pedagogical Explanation: Maintaining the quality manual is a system/prevention activity (QA).
Question 4: Error scenario: Inconsistent drop size from a Pasteur pipette How should this error be classified?
- A. Random error (Correct Answer)
- B. Not an error at all
- C. Systematic error
- D. A gross mistake
Pedagogical Explanation: It scatters measurements unpredictably (affects precision); reduced by replication and statistics.
Question 5: In 0.00450, the significant figures are
- A. 5
- B. 4
- C. 2
- D. 3 (the digits 4, 5, 0) (Correct Answer)
Pedagogical Explanation: Leading zeros are not significant; the trailing zero after the decimal is: 4, 5, 0 = 3 sf.