CHEMVEN

Entropy of Vaporisation by the Boiling-Point Method: Ethanol

To determine ΔH_vap of ethanol by measuring its boiling point at reduced pressure, then find ΔS_vap.

Level: UniversitySafety: Needs supervisionTime: 75 min
Aim of Experiment: To determine ΔH_vap of ethanol by measuring its boiling point at reduced pressure, then find ΔS_vap.

Theoretical Foundations

Boiling point at several external pressures (water aspirator + manometer) gives p-T data; Clausius-Clapeyron slope yields ΔH_vap ≈ 38.6 kJ/mol; ΔS_vap = ΔH_vap/T_b ≈ 110 J/mol·K. Comparing with Trouton's rule revisits experiment 051 with real student data.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Round-bottom flask
  • Condenser
  • Manometer
  • Water aspirator
  • Heating mantle
  • Thermometer

Chemical Reagents

  • Ethanol (absolute)

Step-by-Step Practical Procedure

  1. Set up reduced-pressure boiling apparatus with manometer.
  2. Record boiling T at 4-5 pressures between 200 and 760 mmHg.
  3. Plot ln p vs 1/T; slope = -ΔH_vap/R.
  4. Compute ΔH_vap, then ΔS_vap = ΔH_vap/T_b(760 mmHg).
  5. Compare with Trouton's 85 J/mol·K; explain the deviation.

Observations & Expected Results

Typical student data: ΔH_vap ≈ 37 kJ/mol; ΔS_vap ≈ 105 J/mol·K — above Trouton, confirming ethanol's H-bonded liquid is unusually ordered.

Worked Stoichiometric Calculations

Problem: Typical student data: ln p vs 1/T slope = -4450 K. Find ΔH_vap and ΔS_vap (T_b = 351 K).

Working: ΔH_vap = -R × slope = 8.314 × 4450 = 36,997 J/mol ≈ 37.0 kJ/mol. ΔS_vap = 36,997/351 = 105.4 J/mol·K — above Trouton's constant, as expected for an H-bonded liquid.

Safety Precautions & Hazard Control

  • Supervision: reduced-pressure glassware — implosion risk; use shielding.
  • Ethanol flammable; heating mantle, no open flame.
  • Release vacuum before switching off the aspirator.

Waste Disposal Protocol

Ethanol to organic waste.

Viva Voce Oral Defense Questions & Answers

Q: Why does boiling point fall at reduced pressure?

A: Boiling occurs when vapour pressure equals external pressure; lower external p is matched at lower T.

Q: Derive ΔH_vap from the plot.

A: Clausius-Clapeyron: ln p = -ΔH_vap/RT + const, so slope = -ΔH_vap/R.

Q: Why is ΔS_vap high for ethanol?

A: Hydrogen bonding orders the liquid more than a typical liquid, so vaporisation gains extra entropy.

← Back to Experiments Directory