Relative Lowering of Vapour Pressure: Raoult's Law Check
To verify Raoult's law via the relative lowering of vapour pressure of water by urea.
Theoretical Foundations
Δp/p° = x_solute (for non-volatile solute). Measuring the vapour pressure of a urea solution vs pure water at the same T (differential manometer) gives Δp/p°; comparing with the mole fraction computed from masses tests Raoult's law directly.
Required Apparatus & Chemicals
Laboratory Apparatus
- Differential manometer setup (two flasks, U-tube)
- Thermostat bath
- Balance
- Vacuum pump (gentle)
Chemical Reagents
- Urea (AR grade)
- Distilled water
Step-by-Step Practical Procedure
- Place distilled water in flask A and urea solution (10.0 g urea in 100.0 g water) in flask B.
- Equilibrate both at 25.0 °C.
- Read the manometer difference Δp; measure p° of pure water.
- Compute x_urea from masses.
- Compare Δp/p° with x_urea.
Observations & Expected Results
Typical student data: x_urea = 0.0291; Δp/p° = 0.028 — agreement within ~4%, confirming Raoult's law for this near-ideal solution.
Worked Stoichiometric Calculations
Problem: 10.0 g urea (0.1666 mol) in 100.0 g water (5.551 mol); p° = 23.8 mmHg, Δp = 0.67 mmHg. Test Raoult's law.
Working: x_urea = 0.1666/(0.1666 + 5.551) = 0.02913. Δp/p° = 0.67/23.8 = 0.02815. Agreement within 3.4% — Raoult's law holds (Δp/p° = x_solute).
Safety Precautions & Hazard Control
- Glass vacuum apparatus — implosion screen.
- Strict temperature control; p° is T-sensitive.
- Degas the water to remove dissolved air.
Waste Disposal Protocol
Solutions to drain.
Viva Voce Oral Defense Questions & Answers
Q: State Raoult's law.
A: p_solvent = x_solvent·p°_solvent; equivalently Δp/p° = x_solute for a non-volatile solute.
Q: Why must the solute be non-volatile?
A: A volatile solute would contribute its own vapour pressure, invalidating the simple relation.
Q: How does this connect to boiling-point elevation?
A: Lowered vapour pressure means a higher T is needed for p to reach 1 atm — the same molecular origin as ΔT_b.