CHEMVEN

Cooling Correction in Calorimetry: Extrapolation to Mixing Time

To apply a Newtonian cooling correction to a neutralisation experiment and obtain a truer ΔT.

Level: UniversitySafety: SafeTime: 75 min
Aim of Experiment: To apply a Newtonian cooling correction to a neutralisation experiment and obtain a truer ΔT.

Theoretical Foundations

After mixing, the solution cools approximately by Newton's law of cooling, so the observed maximum is below the true adiabatic rise. Recording T every 30 s before and after mixing and extrapolating the pre- and post-mixing lines back to the mixing time gives the corrected ΔT — the standard Regnault-Pfaundler style correction in simplified form.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Polystyrene cup with lid
  • Thermometer (0.1 °C) or data logger
  • Measuring cylinders
  • Stopwatch
  • Stirrer

Chemical Reagents

  • Hydrochloric acid (1.0 mol/dm³)
  • Sodium hydroxide (1.0 mol/dm³)

Step-by-Step Practical Procedure

  1. Place 50.0 cm³ 1.0 M HCl in the cup; record T every 30 s for 3 min.
  2. At t = 0 add 50.0 cm³ 1.0 M NaOH rapidly and stir.
  3. Continue recording T every 30 s for 5 min.
  4. Plot T vs t; draw the best line through the cooling points and extrapolate back to t = 0.
  5. Read the corrected ΔT from the extrapolated line vs the initial line.
  6. Recompute ΔH_neut and compare with the uncorrected value.

Observations & Expected Results

Typical student data: raw ΔT = 6.5 °C; extrapolated corrected ΔT = 6.9 °C — the corrected ΔH_neut moves from -54.3 to -57.7 kJ/mol, closer to the accepted -57 kJ/mol.

Worked Stoichiometric Calculations

Problem: Typical student data: raw maximum ΔT = 6.5 °C; cooling-corrected ΔT = 6.9 °C (100 g solution, 0.050 mol water). Compare ΔH values.

Working: Uncorrected: q = 100 × 4.18 × 6.5 = 2717 J → ΔH = -54.3 kJ/mol. Corrected: q = 100 × 4.18 × 6.9 = 2884 J → ΔH = -57.7 kJ/mol. The correction recovers the heat lost during the slow cooling tail.

Safety Precautions & Hazard Control

  • Eye protection for acid/base handling.
  • Keep stirring rate constant; cooling rate depends on it.
  • Define t = 0 precisely at the moment of mixing.

Waste Disposal Protocol

Neutralised solution to drain with water.

Viva Voce Oral Defense Questions & Answers

Q: Why extrapolate rather than just take the peak?

A: The peak is already depressed by simultaneous heat loss; extrapolation reconstructs the temperature the mixture would have reached with no loss.

Q: What assumption does the linear extrapolation make?

A: That cooling follows Newton's law (rate proportional to excess temperature) over the short interval, so the T-t curve is locally linear.

Q: When is this correction largest?

A: When the reaction is slow or the calorimeter poorly insulated, so significant cooling occurs before the peak.

← Back to Experiments Directory