Surface Tension Lowering by Soap: Gibbs Surface Excess from Data
To determine the surface excess and molecular area of soap at the air-water interface from surface-tension data.
Theoretical Foundations
Below the CMC, the Gibbs isotherm for a 1:1 ionic surfactant is Gamma = -(1/2RT)·d(gamma)/d(ln c). From measured gamma vs log c, the slope gives Gamma; area per molecule = 1/(Gamma·N_A) (~40-50 A^2 for SDS) - a molecular dimension from macroscopic data.
Required Apparatus & Chemicals
Laboratory Apparatus
- Stalagmometer
- Volumetric flasks
- Thermostat
- Analytical balance
Chemical Reagents
- Sodium dodecyl sulfate (below CMC: 1-6 mM)
- Distilled water
Step-by-Step Practical Procedure
- Prepare SDS solutions 1, 2, 3, 4, 5, 6 mM.
- Measure gamma at 25 C for each.
- Plot gamma vs ln c; find the slope in the linear region.
- Calculate Gamma = -(1/2RT)·slope.
- Compute area per molecule; compare with the known ~45 A^2.
Observations & Expected Results
gamma vs ln c is linear below the CMC with slope ~ -12 mN/m; students obtain area ~45-55 A^2 per molecule.
Worked Stoichiometric Calculations
Problem: Slope d(gamma)/d(ln c) = -0.012 N/m at 298 K. Find Gamma and the area per molecule.
Working: Gamma = -1/(2 x 8.314 x 298) x (-0.012) = 0.012/4955 = 2.42 x 10^-6 mol/m^2. Area = 1/(2.42 x 10^-6 x 6.022 x 10^23) = 6.86 x 10^-19 m^2 = 68.6 A^2. (With the measured slope -0.018 N/m: Gamma = 3.63 x 10^-6, area = 45.7 A^2 - the literature value.)
Safety Precautions & Hazard Control
- Work below the CMC only (linear region).
- Constant temperature.
- Fresh solutions; avoid foam in the stalagmometer.
Waste Disposal Protocol
Dilute SDS to drain.
Viva Voce Oral Defense Questions & Answers
Q: Why the factor 1/2 for ionic surfactants?
A: Both the surfactant ion and its counter-ion are involved in the surface thermodynamics (Gibbs-Duhem for electrolytes).
Q: What does 45 A^2 per molecule tell you?
A: The head-group area of SDS at a saturated interface - a direct molecular footprint.
Q: Why does the plot curve above the CMC?
A: The interface is saturated; added surfactant forms micelles, so gamma stops changing.