Adsorption of Acetic Acid on Charcoal: Effect of Adsorbent Dose
To show that percentage removal rises but uptake per gram (x/m) falls as charcoal dose increases.
Theoretical Foundations
With more adsorbent, more total surface is available so % removal increases - but the equilibrium concentration drops, so each gram adsorbs less (moving down the isotherm). This trade-off governs real adsorber design.
Required Apparatus & Chemicals
Laboratory Apparatus
- Stoppered flasks
- Balance
- Burette
- Filtration set
Chemical Reagents
- Acetic acid (0.25 M)
- Activated charcoal
- Sodium hydroxide (0.10 M)
- Phenolphthalein
Step-by-Step Practical Procedure
- Add 0.5, 1.0, 2.0, 4.0 g charcoal to 50 mL portions of 0.25 M acid.
- Shake 30 min; filter; titrate 10 mL filtrates.
- Calculate % removal and x/m for each dose.
- Plot both against dose.
- Explain the opposing trends via the isotherm.
Observations & Expected Results
Typical student data for doses 0.5, 1.0, 2.0, 4.0 g: % removal 20, 34, 54, 78% while x/m falls 0.30, 0.255, 0.203, 0.146 g/g - the design trade-off is clear.
Worked Stoichiometric Calculations
Problem: With 4.0 g charcoal, c falls from 0.25 to 0.055 M (V = 50 mL, M_acid = 60). Find % removal and x/m.
Working: % removal = (0.25 - 0.055)/0.25 x 100 = 78%. Moles adsorbed = 0.195 x 0.050 = 9.75 x 10^-3 mol; x = 9.75 x 10^-3 x 60 = 0.585 g. x/m = 0.585/4.0 = 0.146 g/g.
Safety Precautions & Hazard Control
- Identical shaking time for all flasks.
- Discard first filtrate.
- Accurate charcoal weighing.
Waste Disposal Protocol
Neutralise filtrates; charcoal to solid waste.
Viva Voce Oral Defense Questions & Answers
Q: Why does x/m fall with dose?
A: More adsorbent lowers the equilibrium concentration, and the isotherm gives less uptake per gram at lower c.
Q: Why does % removal still rise?
A: Total surface area increases, removing more acid overall despite lower per-gram loading.
Q: How do engineers choose the dose?
A: Balancing required % removal against adsorbent cost - the economic optimum on this trade-off curve.