Adsorption Column Chromatography: Separating Dyes on Alumina
To separate a mixture of methylene blue and fluorescein by adsorption chromatography on an alumina column.
Theoretical Foundations
In adsorption chromatography the stationary phase (alumina) adsorbs solutes with different affinities; the less-adsorbed component moves faster with the mobile phase. Differential adsorption - the same phenomenon as the batch isotherms - thus separates mixtures.
Required Apparatus & Chemicals
Laboratory Apparatus
- Glass chromatography column
- Cotton plug
- Beakers
- Droppers
- Measuring cylinders
Chemical Reagents
- Activated alumina (chromatographic)
- Methylene blue + fluorescein mixture
- Ethanol-water (mobile phase)
- Distilled water
Step-by-Step Practical Procedure
- Pack the column with an alumina slurry; let it settle evenly.
- Load 2 mL of dye mixture on top.
- Elute with ethanol-water; collect the fast band.
- Continue eluting; collect the slow band separately.
- Compare colours/spectra of the fractions with the originals.
Observations & Expected Results
Fluorescein (less adsorbed) washes through first as a yellow-green band; methylene blue sticks near the top and elutes later - two clean bands.
Worked Stoichiometric Calculations
Problem: The column holds 20 g alumina; methylene blue's batch uptake is 0.05 g/g. What mass of dye can the column retain before breakthrough?
Working: Capacity = 20 x 0.05 = 1.0 g of methylene blue - far above the few mg loaded, so the column works well below saturation.
Safety Precautions & Hazard Control
- Pack without air bubbles or channels.
- Never let the column run dry.
- Load the sample as a narrow band.
Waste Disposal Protocol
Dye fractions to coloured waste; alumina to solid waste.
Viva Voce Oral Defense Questions & Answers
Q: What decides the elution order?
A: Adsorption affinity for alumina: the less-adsorbed dye travels faster.
Q: How does this connect to the Freundlich isotherm?
A: Both describe the same adsorbate-adsorbent equilibrium; chromatography is that equilibrium repeated in many stages.
Q: Why must the column stay wet?
A: Drying cracks the bed, causing channelling and ruined separation.