Fluorescence vs Phosphorescence: Quinine and Zinc Sulfide
To distinguish fluorescence (instant) from phosphorescence (delayed) using quinine solution and a glow phosphor.
Theoretical Foundations
Fluorescence: singlet excited state emits within nanoseconds of excitation - stops when light stops. Phosphorescence: triplet state (reached by intersystem crossing) emits over seconds to hours - the glow persists in the dark.
Required Apparatus & Chemicals
Laboratory Apparatus
- UV lamp (365 nm)
- Test tubes
- Dark box
Chemical Reagents
- Quinine in dilute H2SO4 (tonic water works)
- Zinc sulfide:copper phosphor powder
- Distilled water
Step-by-Step Practical Procedure
- Darken the room; shine UV on quinine solution - note bright blue fluorescence.
- Switch off UV - the glow vanishes instantly.
- Expose ZnS:Cu powder to UV for 1 min; switch off.
- Observe the green afterglow persisting for minutes.
- Compare lifetimes and colours.
Observations & Expected Results
Quinine: brilliant blue only while UV is on. ZnS:Cu: green glow continuing 5+ minutes after UV off - textbook fluorescence vs phosphorescence.
Worked Stoichiometric Calculations
Problem: Fluorescence lifetime 20 ns; phosphorescence lifetime 5 min. How many times longer is the phosphorescence?
Working: 5 min = 300 s = 3.0 x 10^11 ns. Ratio = 3.0 x 10^11/20 = 1.5 x 10^10 - fifteen billion times longer, reflecting the spin-forbidden triplet emission.
Safety Precautions & Hazard Control
- Do not look directly at the UV lamp.
- Quinine solution is safe at these dilutions.
- Keep phosphor powder dry.
Waste Disposal Protocol
Quinine solution to drain; ZnS powder to solid waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is fluorescence so fast?
A: Singlet-to-singlet emission is spin-allowed, with lifetimes ~10^-9-10^-7 s.
Q: Why is phosphorescence slow?
A: Triplet-to-singlet emission is spin-forbidden, so the excited state lives seconds to hours.
Q: What is intersystem crossing?
A: Non-radiative singlet -> triplet conversion that feeds the phosphorescent state.