Surface Tension by the Drop-Weight Method (Harkins-Brown Correction)
To determine surface tension from the weight of falling drops, applying the Harkins-Brown correction factor.
Theoretical Foundations
The ideal drop-weight relation W = 2·pi·r·gamma overestimates gamma because a neck of liquid remains on the tip. Harkins and Brown tabulated the correction factor f(r/V^(1/3)), giving gamma = W·f/(2·pi·r), accurate to ~0.1%.
Required Apparatus & Chemicals
Laboratory Apparatus
- Stalagmometer or dropping pipette with ground tip
- Analytical balance
- Weighing bottles
- Vernier callipers (tip radius)
- Thermometer
Chemical Reagents
- Distilled water
- Benzene or ethanol (test liquid)
Step-by-Step Practical Procedure
- Measure the tip radius r with vernier callipers.
- Collect a known number of drops (e.g. 30) of water in a tared weighing bottle.
- Weigh; find mean drop weight W1.
- Repeat for the test liquid to get W2.
- Compute r/V^(1/3) for each, read f from Harkins-Brown tables.
- Calculate gamma2 = gamma1 x (W2/W1) x (f2/f1).
Observations & Expected Results
Typical student data: 30 water drops weigh 2.18 g (W = 0.0727 g); correction factors differ by <2%, giving gamma_benzene ~ 28.8 dyn/cm.
Worked Stoichiometric Calculations
Problem: Tip radius 0.35 cm. 30 water drops weigh 2.18 g (f1 = 0.60); 30 benzene drops weigh 0.92 g (f2 = 0.61). gamma_water = 72.8 dyn/cm. Find gamma_benzene.
Working: gamma2 = 72.8 x (0.92/2.18) x (0.61/0.60) = 72.8 x 0.4220 x 1.0167 = 31.2 dyn/cm. With careful slow drops the result approaches the literature 28.9 dyn/cm.
Safety Precautions & Hazard Control
- Drops must form very slowly (~1 per 30 s) for the correction tables to apply.
- Weigh quickly - volatile liquids evaporate from the bottle.
- Keep the tip free of dust and grease.
Waste Disposal Protocol
Organics to waste bottles; water to drain.
Viva Voce Oral Defense Questions & Answers
Q: What physical process does the factor f correct for?
A: The fraction of the drop's liquid that stays behind on the tip as a neck instead of falling.
Q: On what dimensionless ratio does f depend?
A: r/V^(1/3) - the tip radius relative to the drop size.
Q: Why is this method preferred for viscous liquids?
A: Drop weight is independent of flow rate once drops detach quasi-statically, unlike capillary flow methods.