CHEMVEN

Iodine Clock at Several Temperatures: Full Arrhenius Treatment

Determine Ea for the H2O2/I- clock reaction from a full Arrhenius plot over four temperatures.

Level: UniversitySafety: Needs supervisionTime: 90 min
Aim of Experiment: Determine Ea for the H2O2/I- clock reaction from a full Arrhenius plot over four temperatures.

Theoretical Foundations

The clock time t is inversely proportional to k, so ln(1/t) versus 1/T is linear with slope -Ea/R. Four temperatures (20-50 C) give a reliable plot; the two-point equation checks any pair.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conical flasks
  • Water baths at 20, 30, 40, 50 C
  • Thermometer
  • Stopwatch
  • Pipettes

Chemical Reagents

  • Hydrogen peroxide, 0.50 M
  • Potassium iodide, 0.50 M
  • Sulfuric acid, 1.0 M
  • Sodium thiosulfate, 0.050 M
  • Starch solution

Step-by-Step Practical Procedure

  1. Prepare identical clock mixtures.
  2. Measure the end-point time at 20, 30, 40 and 50 C, recording exact temperatures.
  3. Compute ln(1/t) and 1/T for each.
  4. Plot ln(1/t) versus 1/T and find the slope by regression.
  5. Calculate Ea and compare with a two-point value.

Observations & Expected Results

Typical student data: t = 200, 100, 52, 28 s from 20 to 50 C; Arrhenius slope about -6300 K, Ea ~ 52 kJ/mol (illustrative).

Worked Stoichiometric Calculations

Problem: Typical student data: t = 200 s at 293 K and t = 28 s at 323 K. Estimate Ea by the two-point equation.

Working: ln(k2/k1) = ln(200/28) = 1.966. 1/323 - 1/293 = -3.17 x 10^-4 K^-1. Ea = 1.966 x 8.314/3.17 x 10^-4 = 5.16 x 10^4 J/mol, about 52 kJ/mol.

Safety Precautions & Hazard Control

  • Pre-equilibrate all solutions at each temperature.
  • Measure temperature to 0.1 C.
  • Keep concentrations identical across temperatures.

Waste Disposal Protocol

Reduce iodine with thiosulfate; sink disposal with water.

Viva Voce Oral Defense Questions & Answers

Q: Why four temperatures?

A: More points give a better slope and reveal curvature or outliers that two points hide.

Q: What does linearity imply?

A: A single dominant barrier over this range; the mechanism does not change with temperature.

Q: How does Ea compare with the thiosulfate clock?

A: Similar magnitude (~50 kJ/mol): both are aqueous ionic redox reactions with moderate barriers.