CHEMVEN

Starch-Iodine End Point Timing: Thiosulfate Concentration Effect

Verify the clock stoichiometry by showing the end-point time is proportional to thiosulfate concentration.

Level: UniversitySafety: Needs supervisionTime: 45 min
Aim of Experiment: Verify the clock stoichiometry by showing the end-point time is proportional to thiosulfate concentration.

Theoretical Foundations

In the H2O2/I- clock, the time to the starch blue is t = [S2O3^2-]0/(2 x rate) because each I2 consumes two S2O3^2-. At fixed reactant concentrations (fixed rate), t is directly proportional to [S2O3^2-]0.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conical flasks
  • Pipettes
  • Stopwatch
  • Water bath at 25 C
  • White tile

Chemical Reagents

  • Hydrogen peroxide, 0.50 M
  • Potassium iodide, 0.50 M
  • Sulfuric acid, 1.0 M
  • Sodium thiosulfate, 0.020 M, 0.040 M, 0.060 M
  • Starch solution

Step-by-Step Practical Procedure

  1. Prepare identical H2O2/KI/acid/starch mixtures at 25 C.
  2. Add different volumes of thiosulfate (total volume constant).
  3. Start timing at mixing; record the blue end-point time.
  4. Plot t versus thiosulfate volume.
  5. Check the line passes through the origin.

Observations & Expected Results

Typical student data: t = 60, 120, 180 s for 5, 10, 15 mL of 0.040 M thiosulfate; straight line through the origin.

Worked Stoichiometric Calculations

Problem: Typical student data: t = 120 s with 10 mL of 0.040 M thiosulfate in 100 mL total. Calculate the underlying I2 production rate.

Working: [S2O3^2-]0 = 0.040 x 10/100 = 0.0040 M. I2 quenched = 0.0040/2 = 0.0020 M (two thiosulfate per iodine). Rate = 0.0020 M/120 s = 1.67 x 10^-5 M/s.

Safety Precautions & Hazard Control

  • Keep reactant concentrations identical; only thiosulfate varies.
  • Time the first permanent blue.
  • Control temperature.

Waste Disposal Protocol

Reduce iodine and pour to the sink with water.

Viva Voce Oral Defense Questions & Answers

Q: Why through the origin?

A: Zero thiosulfate means the blue appears at t = 0 (no clock delay).

Q: What is the factor of 2?

A: I2 + 2S2O3^2- -> 2I- + S4O6^2-: two thiosulfate per iodine.

Q: How does this calibrate the clock?

A: The slope gives the underlying reaction rate: rate = [S2O3^2-]0/(2t).

← Back to Experiments Directory