Iodination of Propanone by Colorimetry: Continuous Monitoring
Monitor the iodination of propanone continuously with a colorimeter and extract the zero-order rate constant for iodine.
Theoretical Foundations
Iodine absorbs at ~460 nm; absorbance is proportional to [I2]. Since the reaction is zero order in iodine, absorbance falls linearly with time: -dA/dt = epsilon l k[propanone][H+]. The slope gives the rate directly without clock timing.
Required Apparatus & Chemicals
Laboratory Apparatus
- Colorimeter (460 nm) with cuvettes
- Pipettes
- Stopwatch
- Water bath at 25 C
Chemical Reagents
- Propanone, 1.0 M aqueous
- Iodine in KI, 0.0050 M
- Sulfuric acid, 1.0 M
Step-by-Step Practical Procedure
- Thermostat all solutions at 25 C.
- Mix propanone, acid and iodine in a cuvette, start timing, and place it in the colorimeter.
- Record absorbance every 30 s until it reaches zero.
- Plot A versus t.
- Find the rate from the slope divided by (epsilon l), or report dA/dt.
Observations & Expected Results
Typical student data: absorbance falls linearly from 0.60 to 0 over ~400 s; the straight line confirms zero order in iodine.
Worked Stoichiometric Calculations
Problem: Typical student data: A falls from 0.60 to 0.30 in 200 s; epsilon l = 600 L/mol. Find the reaction rate.
Working: dA/dt = 0.30/200 = 1.5 x 10^-3 s^-1. Rate = (dA/dt)/(epsilon l) = 1.5 x 10^-3/600 = 2.5 x 10^-6 M/s.
Safety Precautions & Hazard Control
- Keep the cuvette at constant temperature; remove it only for mixing.
- Iodine stains; wear gloves.
- Propanone is flammable.
Waste Disposal Protocol
Collect iodine waste in the halogenated aqueous waste bottle.
Viva Voce Oral Defense Questions & Answers
Q: Why is the A-t plot linear?
A: Zero order in iodine: [I2] falls at a constant rate, and A is proportional to [I2].
Q: What is the advantage over clock timing?
A: A full curve gives many points and reveals any deviation from zero order.
Q: How would you get k?
A: k = rate/([propanone][H+]) using the known concentrations.