CHEMVEN

Integrated Law Test: Which Order Fits the Data?

Decide the reaction order by testing which integrated rate-law plot is linear, using a supplied concentration-time data set.

Level: UniversitySafety: SafeTime: 60 min
Aim of Experiment: Decide the reaction order by testing which integrated rate-law plot is linear, using a supplied concentration-time data set.

Theoretical Foundations

Zero order: [A] vs t linear. First order: ln[A] vs t linear. Second order: 1/[A] vs t linear. Plotting all three for the same data set identifies the order by the best straight line; this data-analysis exercise uses realistic supplied data.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Spreadsheet or graph paper
  • Supplied data set
  • Scientific calculator
  • Ruler

Chemical Reagents

  • No wet chemicals handled (data-analysis exercise)
  • Supplied printed data set
  • Spreadsheet or graph paper

Step-by-Step Practical Procedure

  1. Tabulate the supplied [A]-time data.
  2. Plot [A] versus t and assess linearity.
  3. Plot ln[A] versus t and assess linearity.
  4. Plot 1/[A] versus t and assess linearity.
  5. Identify the order from the linear plot and find k from its slope.

Observations & Expected Results

Typical supplied data: only the ln[A] plot is linear (slope -0.0040 s^-1); the reaction is first order with k = 4.0 x 10^-3 s^-1.

Worked Stoichiometric Calculations

Problem: Supplied data: the 1/[A] plot is linear with slope 0.25 L/mol/s and intercept 20 L/mol. State the order, k and [A]0.

Working: Second order (1/[A] = kt + 1/[A]0). k = slope = 0.25 L/mol/s; 1/[A]0 = 20, so [A]0 = 0.050 M.

Safety Precautions & Hazard Control

  • Use enough significant figures when computing ln and 1/[A].
  • Judge linearity with residuals, not just by eye.
  • Keep units consistent.

Waste Disposal Protocol

No chemical waste.

Viva Voce Oral Defense Questions & Answers

Q: Write the three integrated laws.

A: [A] = [A]0 - kt; ln[A] = ln[A]0 - kt; 1/[A] = 1/[A]0 + kt.

Q: Can data fit two plots?

A: Approximately, over a narrow range; use the correlation coefficient and residuals to decide.

Q: Why is this method powerful?

A: It needs no rate measurements, only concentration versus time.

← Back to Experiments Directory