CHEMVEN

Aquation of Chloropentaamminecobalt(III): Spectrophotometric Kinetics

Determine the first-order rate constant for the aquation of [CoCl(NH3)5]2+ by visible spectrophotometry.

Level: UniversitySafety: Needs supervisionTime: 90 min
Aim of Experiment: Determine the first-order rate constant for the aquation of [CoCl(NH3)5]2+ by visible spectrophotometry.

Theoretical Foundations

[CoCl(NH3)5]2+ + H2O -> [Co(H2O)(NH3)5]3+ + Cl-. The chloro complex (purple) and aqua complex (pink-red) absorb differently at 530 nm. With water as solvent, the reaction is first order: ln[(A0 - Ainf)/(At - Ainf)] = kt.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Visible spectrophotometer or colorimeter (530 nm)
  • Cuvettes
  • Pipettes
  • Stopwatch
  • Thermostat at 25 C

Chemical Reagents

  • [CoCl(NH3)5]Cl2, solid
  • Distilled water
  • Nitric acid, 0.10 M (to suppress base hydrolysis)

Step-by-Step Practical Procedure

  1. Dissolve the cobalt complex in 0.10 M HNO3 at 25 C and start timing.
  2. Record absorbance at 530 nm every 2 min for 60 min.
  3. Leave a sample to complete reaction for Ainf.
  4. Plot ln[(A0 - Ainf)/(At - Ainf)] versus t.
  5. Find k from the slope.

Observations & Expected Results

Typical student data: absorbance falls from 0.62 to 0.20; the first-order plot is linear with slope ~8.0 x 10^-4 s^-1 (illustrative).

Worked Stoichiometric Calculations

Problem: Typical student data: A0 = 0.62, Ainf = 0.20, At = 0.35 at t = 1200 s. Calculate k.

Working: k = (1/1200) ln[(0.62-0.20)/(0.35-0.20)] = (1/1200) ln(0.42/0.15) = (1/1200)(1.030) = 8.58 x 10^-4 s^-1.

Safety Precautions & Hazard Control

  • Cobalt salts are toxic; wear gloves and avoid ingestion.
  • Keep the acid concentration constant; base hydrolysis is a competing path.
  • Control temperature precisely.

Waste Disposal Protocol

Collect cobalt-containing solutions in the heavy-metal waste bottle.

Viva Voce Oral Defense Questions & Answers

Q: Why is this first order?

A: The rate-determining step is unimolecular loss of Cl- from the complex; water is in huge excess.

Q: Why add nitric acid?

A: To suppress the base-hydrolysis pathway (OH- attack) so only aquation is measured.

Q: What is the mechanism type?

A: Dissociative (D/Id): the Co-Cl bond breaks before water binds.

← Back to Experiments Directory