Theoretical Foundations

2MnO4- + 5C2O4^2- + 16H+ -> 2Mn2+ + 10CO2 + 8H2O. The product Mn2+ catalyses the reaction, so the rate starts slow, accelerates as Mn2+ builds up, then slows as reactants deplete: a sigmoidal (S-shaped) concentration-time curve characteristic of autocatalysis.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conical flasks
  • Burettes
  • Pipettes
  • Stopwatch
  • White tile
  • Colorimeter (optional)
  • Water bath at 25 C

Chemical Reagents

  • Potassium permanganate, 0.020 M
  • Oxalic acid, 0.10 M in 1 M H2SO4
  • Distilled water

Step-by-Step Practical Procedure

  1. Mix fixed volumes of oxalic acid solution and KMnO4 at 25 C and start timing.
  2. Record the purple colour intensity (visually or with a colorimeter at 525 nm) every 30 s.
  3. Continue until the solution is colourless.
  4. Plot absorbance (or colour score) versus time.
  5. Identify the induction period, the steep autocatalytic phase and the final slowing.

Observations & Expected Results

Typical student data: little change for the first ~2 min, then rapid fading between 2 and 5 min, then slow completion; the S-shaped curve is the fingerprint of autocatalysis.

Worked Stoichiometric Calculations

Problem: Typical student data: absorbance falls from 0.80 to 0.40 between t = 150 s and t = 210 s (fastest phase), but only from 0.80 to 0.75 in the first 60 s. What does this show?

Working: The rate increases as the reaction proceeds (0.0067 abs/s in the fast phase vs 0.0008 abs/s initially), consistent with catalysis by the Mn2+ product: autocatalysis.

Safety Precautions & Hazard Control

  • KMnO4 stains skin and is an oxidiser; wear gloves.
  • Oxalic acid is toxic if ingested; handle carefully.
  • Keep the acid concentration constant; the rate depends on [H+].

Waste Disposal Protocol

Reduce residual permanganate with oxalic acid or sulfite, then pour the colourless Mn2+ solution to the sink.

Viva Voce Oral Defense Questions & Answers

Q: What is autocatalysis?

A: Catalysis by a product of the reaction itself, so the rate accelerates as the reaction proceeds.

Q: Why the S-shape?

A: Slow start (little catalyst), fast middle (catalyst built up), slow end (reactants depleted).

Q: How would you prove Mn2+ is the catalyst?

A: Add Mn2+ at the start: the induction period should vanish (see the next experiment).

← Back to Experiments Directory