CHEMVEN

Briggs-Rauscher Oscillating Reaction: Measuring the Oscillation Period

Prepare the Briggs-Rauscher oscillating reaction and measure how the oscillation period changes with temperature.

Level: UniversitySafety: Advanced lab onlyTime: 60 min
Aim of Experiment: Prepare the Briggs-Rauscher oscillating reaction and measure how the oscillation period changes with temperature.

Theoretical Foundations

Bromate oxidises malonic acid in a Mn2+-catalysed cycle with two alternating pathways (radical and non-radical), producing oscillations in [I2]/[I-] seen as amber/blue swings with starch. The period shortens with temperature following Arrhenius-like behaviour of the component steps.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Beakers
  • Measuring cylinders
  • Stopwatch
  • Magnetic stirrer
  • Water baths
  • White background

Chemical Reagents

  • Solution A: KIO3 + H2SO4 (equal volume with Solution B)
  • Solution B: MnSO4 + malonic acid + starch (equal volume with Solution A)
  • Hydrogen peroxide, 30%
  • Distilled water

Step-by-Step Practical Procedure

  1. Prepare solutions A and B as instructed and thermostat at 20 C.
  2. Mix equal volumes with stirring, add H2O2, and start the stopwatch.
  3. Count the colour oscillations (amber to blue) and record the time of each switch for 10 cycles.
  4. Repeat at 30 C and 40 C with fresh mixtures.
  5. Plot the oscillation period versus temperature.

Observations & Expected Results

Typical student data: about 15-25 clear oscillations; period ~30 s at 20 C, ~18 s at 30 C, ~11 s at 40 C; oscillations eventually damp out.

Worked Stoichiometric Calculations

Problem: Typical student data: 10 oscillations take 300 s at 20 C and 180 s at 30 C. Find the period at each temperature and the ratio.

Working: Period = 300/10 = 30 s at 20 C; 180/10 = 18 s at 30 C. Ratio = 30/18 = 1.67: the cycle speeds up markedly with temperature.

Safety Precautions & Hazard Control

  • 30% H2O2 is a strong oxidiser and corrosive; wear goggles and gloves.
  • Concentrated acid mixtures: add acid to water, handle in a fume cupboard.
  • Stir gently and consistently; stirring affects the oscillations.

Waste Disposal Protocol

Neutralise the acidic mixture, reduce iodine with thiosulfate, and dispose via the aqueous oxidiser waste stream.

Viva Voce Oral Defense Questions & Answers

Q: Why does it oscillate instead of going straight to products?

A: Two competing pathways alternately dominate: one makes iodine, the other consumes it, coupled through feedback on [I-].

Q: Is this perpetual motion?

A: No: the oscillations damp out as reactants are consumed; the system moves toward equilibrium throughout.

Q: Why does stirring matter?

A: Oscillations need uniform concentrations; poor mixing creates local inhomogeneities that disrupt the cycle.

← Back to Experiments Directory