CHEMVEN

Iodide-Catalysed Decomposition of H2O2: Determining the Catalytic Rate Law

Determine the rate law for the iodide-catalysed decomposition of hydrogen peroxide, including the order in the iodide catalyst.

Level: UniversitySafety: Needs supervisionTime: 75 min
Aim of Experiment: Determine the rate law for the iodide-catalysed decomposition of hydrogen peroxide, including the order in the iodide catalyst.

Theoretical Foundations

H2O2 + 2I- + 2H+ -> I2 + 2H2O followed by H2O2 + I2 -> 2I- + 2H+ + O2, so iodide is regenerated. With [H2O2] in excess, the initial rate is measured by timing the appearance of iodine (starch end point) for different [I-], giving the order in catalyst from a log-log plot.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conical flasks
  • Burettes
  • Pipettes
  • Stopwatch
  • White tile
  • Water bath at 25 C
  • Measuring cylinders

Chemical Reagents

  • Hydrogen peroxide, 0.50 M
  • Potassium iodide, 0.20 M
  • Sulfuric acid, 1.0 M
  • Starch solution, 1%
  • Sodium thiosulfate, 0.050 M
  • Distilled water

Step-by-Step Practical Procedure

  1. Mix fixed volumes of H2O2, acid, starch and a fixed small volume of thiosulfate in a flask at 25 C.
  2. Add a measured volume of KI solution, start the stopwatch, and swirl.
  3. The solution stays colourless while thiosulfate consumes iodine; record the time for the sudden blue-black starch colour.
  4. Repeat with different KI volumes, keeping the total volume constant.
  5. Calculate initial rate = [S2O3^2-]consumed/t and plot log(rate) vs log[I-].

Observations & Expected Results

Typical student data: doubling [KI] halves the time to the blue colour; the log-log slope is 1.0, so the reaction is first order in iodide catalyst.

Worked Stoichiometric Calculations

Problem: Typical student data: with [I-] = 0.010 M, t = 90 s; with [I-] = 0.020 M, t = 46 s (fixed thiosulfate). Find the order in iodide.

Working: Rate ~ 1/t: rate ratio = 90/46 = 1.96; concentration ratio = 2.0. 2.0^n = 1.96 gives n = 1: first order in iodide.

Safety Precautions & Hazard Control

  • Iodine stains; wear gloves.
  • Keep [H2O2] and [H+] in large excess so only [I-] varies.
  • Time the first permanent blue colour consistently.
  • Control temperature at 25 C.

Waste Disposal Protocol

Reduce residual iodine with thiosulfate, then pour the colourless solution to the sink with water.

Viva Voce Oral Defense Questions & Answers

Q: Is iodide a catalyst here?

A: Yes: it is consumed in the first step and regenerated in the second, so its concentration is unchanged overall.

Q: Why add thiosulfate?

A: It quenches the iodine produced, creating a sharp clock end point so the initial rate can be timed.

Q: What is the overall stoichiometry?

A: 2H2O2 -> 2H2O + O2; iodide cancels out.

← Back to Experiments Directory