Thiosulfate-Acid Clock: Activation Energy by the Arrhenius Equation
Determine the activation energy of the thiosulfate-acid reaction from rate measurements at several temperatures using the Arrhenius equation.
Theoretical Foundations
k = A e^(-Ea/RT), so ln k = ln A - Ea/RT. With rate proportional to 1/t, a plot of ln(1/t) versus 1/T is linear with slope -Ea/R. The two-point form ln(k2/k1) = -(Ea/R)(1/T2 - 1/T1) gives Ea directly from two temperatures.
Required Apparatus & Chemicals
Laboratory Apparatus
- Conical flasks
- Water baths
- Thermometer (0.1 C)
- Stopwatch
- Cross paper
- Pipettes
Chemical Reagents
- Sodium thiosulfate, 0.10 M
- Hydrochloric acid, 1.0 M
- Distilled water
- Ice
Step-by-Step Practical Procedure
- Prepare identical reaction mixtures and measure disappearance times at 20, 30, 40 and 50 C as in the temperature experiment.
- Record the exact temperature of each mixture.
- Calculate ln(1/t) and 1/T (kelvin) for each run.
- Plot ln(1/t) against 1/T and find the slope.
- Compute Ea = -slope x R (R = 8.314 J/mol/K).
Observations & Expected Results
Typical student data: the Arrhenius plot is linear; slope about -6100 K, giving Ea near 51 kJ/mol. This is an illustrative student value, not a literature constant.
Worked Stoichiometric Calculations
Problem: Typical student data: t = 150 s at 293 K and t = 75 s at 303 K. Estimate Ea using the two-point Arrhenius equation.
Working: ln(k2/k1) = ln(t1/t2) = ln(150/75) = 0.693. 1/T2 - 1/T1 = 1/303 - 1/293 = -1.13 x 10^-4 K^-1. Ea = 0.693 x 8.314 / 1.13 x 10^-4 = 5.1 x 10^4 J/mol, about 51 kJ/mol.
Safety Precautions & Hazard Control
- Measure temperature to 0.1 C; Ea is sensitive to T errors.
- Use kelvin in the 1/T calculation.
- Ventilate the SO2 produced.
- Keep concentrations identical at every temperature.
Waste Disposal Protocol
Decant and dilute liquids to the sink; bin sulfur solids.
Viva Voce Oral Defense Questions & Answers
Q: What is the physical meaning of Ea?
A: The minimum energy colliding molecules need for a successful reaction; the height of the energy barrier.
Q: What does the intercept of the Arrhenius plot give?
A: ln A, where A is the pre-exponential (frequency) factor.
Q: Why plot 1/T rather than T?
A: Because the Arrhenius equation is linear in 1/T, giving Ea directly from the slope.