CHEMVEN

Thiosulfate-Acid Clock: Activation Energy by the Arrhenius Equation

Determine the activation energy of the thiosulfate-acid reaction from rate measurements at several temperatures using the Arrhenius equation.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: Determine the activation energy of the thiosulfate-acid reaction from rate measurements at several temperatures using the Arrhenius equation.

Theoretical Foundations

k = A e^(-Ea/RT), so ln k = ln A - Ea/RT. With rate proportional to 1/t, a plot of ln(1/t) versus 1/T is linear with slope -Ea/R. The two-point form ln(k2/k1) = -(Ea/R)(1/T2 - 1/T1) gives Ea directly from two temperatures.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conical flasks
  • Water baths
  • Thermometer (0.1 C)
  • Stopwatch
  • Cross paper
  • Pipettes

Chemical Reagents

  • Sodium thiosulfate, 0.10 M
  • Hydrochloric acid, 1.0 M
  • Distilled water
  • Ice

Step-by-Step Practical Procedure

  1. Prepare identical reaction mixtures and measure disappearance times at 20, 30, 40 and 50 C as in the temperature experiment.
  2. Record the exact temperature of each mixture.
  3. Calculate ln(1/t) and 1/T (kelvin) for each run.
  4. Plot ln(1/t) against 1/T and find the slope.
  5. Compute Ea = -slope x R (R = 8.314 J/mol/K).

Observations & Expected Results

Typical student data: the Arrhenius plot is linear; slope about -6100 K, giving Ea near 51 kJ/mol. This is an illustrative student value, not a literature constant.

Worked Stoichiometric Calculations

Problem: Typical student data: t = 150 s at 293 K and t = 75 s at 303 K. Estimate Ea using the two-point Arrhenius equation.

Working: ln(k2/k1) = ln(t1/t2) = ln(150/75) = 0.693. 1/T2 - 1/T1 = 1/303 - 1/293 = -1.13 x 10^-4 K^-1. Ea = 0.693 x 8.314 / 1.13 x 10^-4 = 5.1 x 10^4 J/mol, about 51 kJ/mol.

Safety Precautions & Hazard Control

  • Measure temperature to 0.1 C; Ea is sensitive to T errors.
  • Use kelvin in the 1/T calculation.
  • Ventilate the SO2 produced.
  • Keep concentrations identical at every temperature.

Waste Disposal Protocol

Decant and dilute liquids to the sink; bin sulfur solids.

Viva Voce Oral Defense Questions & Answers

Q: What is the physical meaning of Ea?

A: The minimum energy colliding molecules need for a successful reaction; the height of the energy barrier.

Q: What does the intercept of the Arrhenius plot give?

A: ln A, where A is the pre-exponential (frequency) factor.

Q: Why plot 1/T rather than T?

A: Because the Arrhenius equation is linear in 1/T, giving Ea directly from the slope.

← Back to Experiments Directory