Constructing a Leclanche Dry Cell
To build a working dry cell and relate its voltage to the Zn-MnO2 chemistry.
Theoretical Foundations
Anode: Zn -> Zn2+ + 2e- (zinc can). Cathode: 2MnO2 + 2NH4+ + 2e- -> Mn2O3 + 2NH3 + H2O (carbon rod in MnO2/NH4Cl paste). E ~ 1.5 V. The 'dry' cell uses a moist paste, not a liquid electrolyte.
Required Apparatus & Chemicals
Laboratory Apparatus
- Zinc can (or zinc foil cup)
- Carbon rod
- Beaker
- Digital voltmeter
- Small bulb
Chemical Reagents
- Manganese dioxide powder
- Ammonium chloride
- Zinc chloride
- Starch or flour (paste thickener)
- Water
Step-by-Step Practical Procedure
- Mix MnO2, NH4Cl, ZnCl2 and starch into a thick paste with water.
- Pack the paste around the carbon rod inside the zinc can.
- Seal the top with wax or tape, leaving terminals exposed.
- Measure the open-circuit voltage.
- Connect the bulb and observe.
Observations & Expected Results
Voltage ~1.4-1.55 V; bulb lights, dimming as polarisation sets in.
Worked Stoichiometric Calculations
Problem: Four such cells in series give what voltage? What current flows through a 30 ohm bulb if each cell has 1 ohm internal resistance?
Working: Voltage = 4 x 1.5 = 6.0 V. Total resistance = 4 x 1 + 30 = 34 ohm. I = 6.0/34 = 0.176 A, about 0.18 A.
Safety Precautions & Hazard Control
- MnO2 dust: avoid inhalation.
- NH4Cl paste irritates skin; wear gloves.
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Dismantle and dispose of cell components as solid chemical waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is it called a 'dry' cell?
A: The electrolyte is a moist paste immobilised with starch, so nothing spills - though it is not truly dry.
Q: What limits the shelf life of a Leclanche cell?
A: The acidic NH4Cl paste slowly corrodes the zinc can even on open circuit (self-discharge).