Model Hydrogen-Oxygen Fuel Cell
To build a working H2-O2 fuel cell model and measure its voltage.
Theoretical Foundations
Anode: 2H2 -> 4H+ + 4e-; cathode: O2 + 4H+ + 4e- -> 2H2O; overall 2H2 + O2 -> 2H2O with Edeg = 1.23 V. Unlike a battery, the fuel cell runs as long as gases are supplied - a galvanic cell with continuous reactants.
Required Apparatus & Chemicals
Laboratory Apparatus
- Two Pt-coated electrodes (or Pt wire)
- U-tube or divided cell
- DC supply (for generating gases in situ)
- Digital voltmeter
- Salt bridge membrane
Chemical Reagents
- Dilute H2SO4 (electrolyte)
- Hydrogen and oxygen (generated in situ by prior electrolysis)
- Distilled water (for rinsing glassware and electrodes)
Step-by-Step Practical Procedure
- Electrolyse dilute H2SO4 briefly to generate H2 and O2 over the two Pt electrodes.
- Disconnect the supply and immediately connect the voltmeter.
- Record the open-circuit voltage.
- Connect a small load (LED with resistor) and note it lights briefly.
- Compare the measured ~1.0 V with the theoretical 1.23 V.
Observations & Expected Results
Open-circuit ~0.9-1.1 V; LED glows while the stored gases last.
Worked Stoichiometric Calculations
Problem: Calculate Edeg for the H2-O2 fuel cell from Edeg(O2/H2O) = +1.23 V and Edeg(H+/H2) = 0.00 V.
Working: Edegcell = 1.23 - 0.00 = 1.23 V.
Safety Precautions & Hazard Control
- H2/O2 mixtures are explosive - generate only small volumes, no flames.
- Vent gases safely after the experiment.
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Dilute acid can be neutralised and drained.
Viva Voce Oral Defense Questions & Answers
Q: How does a fuel cell differ from a galvanic cell?
A: Reactants are supplied continuously from outside, so it does not 'run down' like a battery with finite internal reactants.
Q: Why is the measured voltage below 1.23 V?
A: Activation overvoltages at the electrodes, especially sluggish O2 reduction, plus ohmic losses.