Solubility Product of AgCl by EMF Measurement
To determine Ksp of silver chloride from the EMF of a suitable cell.
Theoretical Foundations
Cell: Ag|Ag+(1 M)||Cl-(1 M)|AgCl|Ag. Edegcell = Edeg(AgCl/Ag) - Edeg(Ag+/Ag) = 0.222 - 0.799 = -0.577 V. For AgCl(s) <=> Ag+ + Cl- (n = 1), log Ksp = nEdeg/0.0591 = -0.577/0.0591, giving Ksp ~ 1.7 x 10^-10.
Required Apparatus & Chemicals
Laboratory Apparatus
- Silver wires
- Beaker with AgCl-coated wire
- Salt bridge
- Digital voltmeter
Chemical Reagents
- AgNO3 (1.0 M)
- KCl (1.0 M)
- AgCl (solid)
Step-by-Step Practical Procedure
- Prepare an AgCl-coated silver wire (anodise Ag in KCl).
- Set up Ag|Ag+(1 M) and AgCl|Ag|Cl-(1 M) half-cells.
- Join with a salt bridge and measure Ecell.
- Compute Edegcell and hence log Ksp.
- Compare with the literature 1.8 x 10^-10.
Observations & Expected Results
Typical Ecell ~ -0.577 V (Ag+ side positive); Ksp calculates to ~1.5-1.8 x 10^-10.
Worked Stoichiometric Calculations
Problem: Edegcell = -0.577 V for the AgCl dissolution cell (n = 1). Calculate Ksp at 25 C.
Working: log Ksp = 1 x (-0.577)/0.0591 = -9.764. Ksp = 10^-9.764 = 1.72 x 10^-10, about 1.7 x 10^-10.
Safety Precautions & Hazard Control
- AgNO3 stains; wear gloves.
- Keep AgCl electrodes in the dark.
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Collect silver waste for recovery.
Viva Voce Oral Defense Questions & Answers
Q: Why is Edegcell negative here?
A: Dissolution of AgCl is non-spontaneous under standard conditions - consistent with its tiny Ksp.
Q: Why is this method better than direct analysis?
A: The solubility (~10^-5 M) is far too low for titration; EMF measures the equilibrium constant directly.