Anodising Aluminium for Corrosion Protection
To anodise aluminium, thickening its protective oxide film electrolytically.
Theoretical Foundations
Aluminium is the anode in dilute H2SO4: 2Al + 3H2O -> Al2O3 + 6H+ + 6e-. The porous Al2O3 layer grows outward; sealing in boiling water closes the pores. The film is hard, insulating and corrosion-resistant, and takes up dyes.
Required Apparatus & Chemicals
Laboratory Apparatus
- Aluminium strip (anode)
- Lead or graphite cathode
- Beaker
- DC supply
- Ammeter
- Dye bath (optional)
Chemical Reagents
- Sulphuric acid (1.5 M)
- Fabric dye (optional)
- Distilled water (for rinsing glassware and electrodes)
Step-by-Step Practical Procedure
- Degrease the Al strip in warm detergent and rinse.
- Anodise at ~1.5 A/dm2 for 30 minutes in 1.5 M H2SO4.
- Rinse and optionally dye in hot dye solution.
- Seal by boiling in distilled water for 15 minutes.
- Compare corrosion resistance with untreated Al in salt water.
Observations & Expected Results
Dull grey adherent oxide film; dyed samples take strong colour; anodised strip resists salt-water pitting far better.
Worked Stoichiometric Calculations
Problem: An Al strip of area 20 cm2 (one side) is anodised at 0.30 A for 30 min. What mass of Al2O3 forms? (M = 102, 6e- per Al2O3)
Working: Q = 0.30 x 1800 = 540 C. Moles e- = 540/96485 = 0.005597 mol. Moles Al2O3 = 0.005597/6 = 0.000933 mol. Mass = 0.000933 x 102 = 0.0952 g, about 95 mg.
Safety Precautions & Hazard Control
- H2SO4 is corrosive; wear gloves and eye protection.
- Keep the cathode from touching the anode.
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Neutralise the acid bath before disposal.
Viva Voce Oral Defense Questions & Answers
Q: Why is aluminium the anode and not the cathode?
A: Oxide grows by oxidation of Al; as cathode it would just evolve H2 with no film growth.
Q: What does sealing in boiling water do?
A: It hydrates the porous alumina to boehmite, closing the pores and locking in dye and corrosion resistance.