CHEMVEN

Predicting the Products of Electrolysis: A Systematic Study

To predict and verify the products of electrolysis for six different electrolytes.

Level: UniversitySafety: Needs supervisionTime: 90 min
Aim of Experiment: To predict and verify the products of electrolysis for six different electrolytes.

Theoretical Foundations

Product prediction rules: at the cathode, the species with the more positive reduction potential discharges (e.g. Cu2+ before H2O; H2O before Na+). At the anode, the species with the lower oxidation potential discharges, modified by concentration and overvoltage (e.g. concentrated Cl- gives Cl2).

Required Apparatus & Chemicals

Laboratory Apparatus

  • Beakers
  • Graphite and copper electrodes
  • DC supply
  • Test tubes
  • pH paper
  • Splints

Chemical Reagents

  • CuSO4 (0.5 M)
  • NaCl (concentrated)
  • Na2SO4 (0.5 M)
  • KI (0.5 M)
  • CuSO4 with Cu electrodes
  • Dilute H2SO4

Step-by-Step Practical Procedure

  1. For each electrolyte, predict cathode and anode products using Edeg values and the rules.
  2. Electrolyse with the specified electrodes at ~0.5 A.
  3. Test gases and solution changes (pH, colour).
  4. Tabulate predicted vs observed products.
  5. Explain any discrepancies (overvoltage, concentration effects).

Observations & Expected Results

Predictions hold: CuSO4/Pt gives Cu + O2; brine gives H2 + Cl2; Na2SO4 gives H2 + O2; KI gives H2 + I2; CuSO4/Cu gives Cu transfer; H2SO4 gives H2 + O2.

Worked Stoichiometric Calculations

Problem: Predict the products of electrolysing concentrated NaCl with graphite electrodes and justify with Edeg values.

Working: Possible cathode: Na+ (-2.71 V) vs H2O (-0.83 V at pH 7 as 2H2O + 2e- -> H2 + 2OH-) - water reduces more easily, so H2. Possible anode: Cl- (+1.36 V) vs H2O (+1.23 V) - O2 is thermodynamically favoured, but high [Cl-] and large O2 overvoltage on graphite make Cl2 the observed product.

Safety Precautions & Hazard Control

  • Vent Cl2 in a fume hood.
  • Keep electrode pairs and predictions labelled to avoid mix-ups.
  • Switch off the power supply before changing any connections.

Waste Disposal Protocol

Neutralise acidic/alkaline liquors; heavy metals to the labelled bottle.

Viva Voce Oral Defense Questions & Answers

Q: Why does Na+ never discharge from aqueous solution?

A: Its reduction potential (-2.71 V) is far more negative than water reduction, so water is always reduced first.

Q: What is overvoltage and why does it matter here?

A: The extra voltage beyond the reversible value needed to drive gas evolution at a practical rate; it lets Cl2 beat O2 kinetically at the anode.

← Back to Experiments Directory