Determining the Faraday Constant by Copper Deposition
To determine the Faraday constant F experimentally from copper coulometry.
Theoretical Foundations
From m = Q x M/(nF), F = I x t x M/(n x m). Measuring the charge passed and the copper mass deposited gives F directly; the accepted value is 96,485 C/mol.
Required Apparatus & Chemicals
Laboratory Apparatus
- Copper voltameter
- DC supply
- Ammeter
- Stopwatch
- Analytical balance
- Rheostat
Chemical Reagents
- CuSO4 (0.5 M, acidified)
- Distilled water (for rinsing the cathode)
- Acetone (for final drying of the cathode)
Step-by-Step Practical Procedure
- Weigh the Cu cathode accurately.
- Pass 2.0 A for exactly 30 minutes at constant current.
- Re-weigh the cathode to find the deposited mass.
- Calculate F = I x t x M/(n x m) with M = 63.5, n = 2.
- Compare with 96,485 C/mol.
Observations & Expected Results
Typical deposit ~1.18 g gives F ~ 96,000-97,000 C/mol.
Worked Stoichiometric Calculations
Problem: With 2.0 A for 30 min, 1.180 g Cu deposits. Calculate F.
Working: Q = 3600 C. Moles Cu = 1.180/63.5 = 0.018583 mol. Moles e- = 2 x 0.018583 = 0.037166 mol. F = 3600/0.037166 = 96,862 C/mol, within 0.4% of 96,485 C/mol.
Safety Precautions & Hazard Control
- Timing and current must be precise; use a stopwatch.
- Ensure 100% current efficiency (no H2 evolution).
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Return the bath to the electroplating waste bottle.
Viva Voce Oral Defense Questions & Answers
Q: What does the Faraday constant represent physically?
A: The charge carried by one mole of electrons: F = NA x e = 96,485 C/mol.
Q: Why is copper preferred over silver for student coulometry?
A: Copper baths are cheap, stable and give adherent deposits; silver nitrate is costly and light-sensitive.