Copper Concentration Cell: EMF from Concentration Difference Alone
To build a concentration cell and show its EMF follows the Nernst equation with Edegcell = 0.
Theoretical Foundations
In Cu|Cu2+(c1)||Cu2+(c2)|Cu both electrodes are identical, so Edegcell = 0 and E = (0.0591/2) log(c2/c1) at 25 C, where c2 > c1. The cell runs by diluting the concentrated side and concentrating the dilute side until c1 = c2.
Required Apparatus & Chemicals
Laboratory Apparatus
- Two copper strips
- Two 100 mL beakers
- Salt bridge
- Digital voltmeter
- Volumetric flasks
- Pipettes
- Connecting wires
Chemical Reagents
- CuSO4 (0.10 M and 0.0010 M)
- KNO3 (salt bridge)
- Distilled water (for rinsing glassware and electrodes)
Step-by-Step Practical Procedure
- Prepare 0.10 M and 0.0010 M CuSO4 solutions.
- Place a Cu strip in each and join with a salt bridge.
- Identify the positive terminal (concentrated side) with the voltmeter.
- Record the EMF.
- Calculate the theoretical EMF and compare.
Observations & Expected Results
Typical reading ~0.058-0.060 V, concentrated side positive.
Worked Stoichiometric Calculations
Problem: Calculate E for Cu|Cu2+(0.0010 M)||Cu2+(0.10 M)|Cu at 25 C.
Working: E = (0.0591/2) log(0.10/0.0010) = 0.02955 x log(100) = 0.02955 x 2 = 0.0591 V, about 59 mV.
Safety Precautions & Hazard Control
- Do not confuse the two concentrations; label beakers clearly.
- Avoid contaminating the dilute solution.
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Collect CuSO4 solutions in the heavy-metal waste container.
Viva Voce Oral Defense Questions & Answers
Q: Why is Edegcell = 0 for a concentration cell?
A: Both half-reactions are chemically identical, so their standard potentials cancel exactly.
Q: What is the cell EMF when c1 = c2?
A: Zero - with no concentration difference there is no driving force.