Standard EMF of the Silver-Zinc Cell
To measure the EMF of the Ag-Zn cell and compare it with the value from standard potentials.
Theoretical Foundations
For Zn(s)|Zn2+(1 M)||Ag+(1 M)|Ag(s): Edegcell = Edeg(Ag+/Ag) - Edeg(Zn2+/Zn) = 0.80 - (-0.76) = 1.56 V. The large EMF reflects the wide separation of Ag and Zn in the electrochemical series.
Required Apparatus & Chemicals
Laboratory Apparatus
- Zn strip
- Silver wire or strip
- Two 100 mL beakers
- Salt bridge
- Digital voltmeter
- Connecting wires
Chemical Reagents
- ZnSO4 (1.0 M)
- AgNO3 (0.10 M)
- KNO3 (salt bridge)
Step-by-Step Practical Procedure
- Set up the Zn half-cell in 1.0 M ZnSO4.
- Set up the Ag half-cell in 0.10 M AgNO3 (note: non-standard concentration).
- Connect via salt bridge and measure the EMF.
- Correct the measured value to standard conditions with the Nernst equation.
- Compare with 1.56 V.
Observations & Expected Results
Measured ~1.50 V with 0.10 M Ag+; Nernst correction adds 0.0591 V, giving ~1.56 V at standard conditions.
Worked Stoichiometric Calculations
Problem: Correct the measured 1.50 V (with [Ag+] = 0.10 M) to standard 1.0 M Ag+ at 25 C for the reaction Zn + 2Ag+ -> Zn2+ + 2Ag.
Working: E = Edeg - (0.0591/2) log([Zn2+]/[Ag+]^2) = 1.56 - 0.02955 log(1.0/0.01) = 1.56 - 0.02955 x 2 = 1.56 - 0.0591 = 1.50 V. The measured 1.50 V matches; reversing gives Edeg = 1.56 V.
Safety Precautions & Hazard Control
- AgNO3 stains skin; wear gloves and avoid light exposure of solutions.
- Keep Ag+ solutions away from chloride contamination.
- Switch off the power supply before changing any connections.
Waste Disposal Protocol
Collect silver waste separately for recovery.
Viva Voce Oral Defense Questions & Answers
Q: Why use 0.10 M AgNO3 instead of 1.0 M?
A: Silver nitrate is expensive and 1.0 M Ag+ is prone to precipitation; the Nernst correction restores the standard value.
Q: Why is the Ag-Zn EMF larger than the Daniell EMF?
A: Ag+ is a much stronger oxidising agent (Edeg = +0.80 V) than Cu2+ (+0.34 V), giving a bigger gap from Zn (-0.76 V).