CHEMVEN

Standard EMF of the Silver-Zinc Cell

To measure the EMF of the Ag-Zn cell and compare it with the value from standard potentials.

Level: UniversitySafety: Needs supervisionTime: 50 min
Aim of Experiment: To measure the EMF of the Ag-Zn cell and compare it with the value from standard potentials.

Theoretical Foundations

For Zn(s)|Zn2+(1 M)||Ag+(1 M)|Ag(s): Edegcell = Edeg(Ag+/Ag) - Edeg(Zn2+/Zn) = 0.80 - (-0.76) = 1.56 V. The large EMF reflects the wide separation of Ag and Zn in the electrochemical series.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Zn strip
  • Silver wire or strip
  • Two 100 mL beakers
  • Salt bridge
  • Digital voltmeter
  • Connecting wires

Chemical Reagents

  • ZnSO4 (1.0 M)
  • AgNO3 (0.10 M)
  • KNO3 (salt bridge)

Step-by-Step Practical Procedure

  1. Set up the Zn half-cell in 1.0 M ZnSO4.
  2. Set up the Ag half-cell in 0.10 M AgNO3 (note: non-standard concentration).
  3. Connect via salt bridge and measure the EMF.
  4. Correct the measured value to standard conditions with the Nernst equation.
  5. Compare with 1.56 V.

Observations & Expected Results

Measured ~1.50 V with 0.10 M Ag+; Nernst correction adds 0.0591 V, giving ~1.56 V at standard conditions.

Worked Stoichiometric Calculations

Problem: Correct the measured 1.50 V (with [Ag+] = 0.10 M) to standard 1.0 M Ag+ at 25 C for the reaction Zn + 2Ag+ -> Zn2+ + 2Ag.

Working: E = Edeg - (0.0591/2) log([Zn2+]/[Ag+]^2) = 1.56 - 0.02955 log(1.0/0.01) = 1.56 - 0.02955 x 2 = 1.56 - 0.0591 = 1.50 V. The measured 1.50 V matches; reversing gives Edeg = 1.56 V.

Safety Precautions & Hazard Control

  • AgNO3 stains skin; wear gloves and avoid light exposure of solutions.
  • Keep Ag+ solutions away from chloride contamination.
  • Switch off the power supply before changing any connections.

Waste Disposal Protocol

Collect silver waste separately for recovery.

Viva Voce Oral Defense Questions & Answers

Q: Why use 0.10 M AgNO3 instead of 1.0 M?

A: Silver nitrate is expensive and 1.0 M Ag+ is prone to precipitation; the Nernst correction restores the standard value.

Q: Why is the Ag-Zn EMF larger than the Daniell EMF?

A: Ag+ is a much stronger oxidising agent (Edeg = +0.80 V) than Cu2+ (+0.34 V), giving a bigger gap from Zn (-0.76 V).