CHEMVEN

Predicting Spontaneous Redox Reactions from Edeg Values

To predict and test whether given redox reactions are spontaneous using standard potentials.

Level: UniversitySafety: SafeTime: 45 min
Aim of Experiment: To predict and test whether given redox reactions are spontaneous using standard potentials.

Theoretical Foundations

For any redox pair, Edegcell = Edeg(oxidant) - Edeg(reductant). If positive, DeltaGdeg = -nFEdeg is negative and the reaction is spontaneous under standard conditions. Predictions are tested by mixing the reagents and observing.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Test tubes and rack
  • Droppers
  • White tile
  • Glass stirring rod
  • Waste beaker

Chemical Reagents

  • KMnO4 (0.01 M)
  • FeSO4 (0.1 M, acidified)
  • KI (0.1 M)
  • CuSO4 (0.5 M)
  • ZnSO4 (0.5 M)
  • Zinc granules
  • Dilute H2SO4

Step-by-Step Practical Procedure

  1. Predict Edegcell for: MnO4- + Fe2+, I- + Fe3+(skip), Zn + Cu2+, Cu + Zn2+.
  2. Add acidified KMnO4 to FeSO4 solution and observe.
  3. Add Zn granules to CuSO4 solution and observe.
  4. Add Cu turnings to ZnSO4 solution and observe.
  5. Compare every observation with the prediction.

Observations & Expected Results

KMnO4 purple discharged by Fe2+ (spontaneous). Zn granules get copper coating (spontaneous). No change with Cu in ZnSO4 (non-spontaneous).

Worked Stoichiometric Calculations

Problem: Edeg(MnO4-/Mn2+) = +1.51 V, Edeg(Fe3+/Fe2+) = +0.77 V. Calculate Edegcell and DeltaGdeg (n = 5) for MnO4- oxidising Fe2+.

Working: Edegcell = 1.51 - 0.77 = 0.74 V. DeltaGdeg = -5 x 96485 x 0.74 = -356,995 J/mol, about -357 kJ/mol: strongly spontaneous.

Safety Precautions & Hazard Control

  • KMnO4 stains; wear gloves.
  • Acidified solutions: handle with care.
  • Wipe up any spills immediately and keep the bench dry.

Waste Disposal Protocol

Collect manganese and heavy-metal solutions in the labelled waste bottles.

Viva Voce Oral Defense Questions & Answers

Q: A positive Edegcell guarantees spontaneity, but does the reaction always occur quickly?

A: No - thermodynamics says nothing about rate; some spontaneous redox reactions are kinetically very slow without a catalyst.

Q: Can Edeg values predict reactions in non-standard conditions?

A: Only qualitatively; the Nernst equation must be used with actual concentrations to get the true E.

← Back to Experiments Directory