CHEMVEN

Determining the Standard Electrode Potential of Zinc

To determine Edeg(Zn2+/Zn) by coupling the zinc electrode to a standard copper electrode.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To determine Edeg(Zn2+/Zn) by coupling the zinc electrode to a standard copper electrode.

Theoretical Foundations

Standard electrode potentials are measured against the standard hydrogen electrode (SHE, 0.00 V). In practice a secondary reference such as the Cu2+/Cu electrode (Edeg = +0.34 V) is used: Edeg(Zn2+/Zn) = Edeg(Cu2+/Cu) - Ecell, where Ecell is the measured EMF of Zn|Zn2+(1 M)||Cu2+(1 M)|Cu.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Zn and Cu strips
  • Two 100 mL beakers
  • Salt bridge
  • Digital voltmeter (high impedance)
  • Connecting wires
  • Sandpaper
  • Volumetric flask

Chemical Reagents

  • ZnSO4 (1.00 M)
  • CuSO4 (1.00 M)
  • KNO3 (salt bridge)

Step-by-Step Practical Procedure

  1. Prepare exactly 1.00 M ZnSO4 and CuSO4 solutions.
  2. Clean both electrodes and set up the cell with a salt bridge.
  3. Measure the EMF three times and take the mean.
  4. Calculate Edeg(Zn2+/Zn) = 0.34 - Ecell.
  5. Compare with the literature value -0.76 V and compute the percentage error.

Observations & Expected Results

Typical measured Ecell = 1.09-1.10 V, giving Edeg(Zn2+/Zn) = -0.75 to -0.76 V.

Worked Stoichiometric Calculations

Problem: A student measures Ecell = 1.08 V for Zn|Zn2+(1 M)||Cu2+(1 M)|Cu. Calculate Edeg(Zn2+/Zn) and the percentage error versus -0.76 V.

Working: Edeg = 0.34 - 1.08 = -0.74 V. Percentage error = |(-0.74) - (-0.76)|/0.76 x 100 = 0.02/0.76 x 100 = 2.6%.

Safety Precautions & Hazard Control

  • Concentrations must be as close to 1.00 M as possible.
  • Use a high-impedance voltmeter so the cell is not drained.
  • Switch off the power supply before changing any connections.

Waste Disposal Protocol

Collect Zn and Cu solutions in the heavy-metal waste container.

Viva Voce Oral Defense Questions & Answers

Q: Why is the hydrogen electrode inconvenient for routine use?

A: It needs a continuous supply of pure H2 gas at 1 atm over platinised platinum in 1 M H+ - awkward and hazardous to maintain.

Q: What does the negative sign of Edeg(Zn2+/Zn) mean?

A: Zn is a stronger reducing agent than H2; it is oxidised more readily, so the Zn electrode is negative relative to SHE.

← Back to Experiments Directory