Liquid Junction Potential: Cell Without a Salt Bridge

To observe the liquid junction potential and EMF decay when electrolytes mix directly.

Level: UniversitySafety: Needs supervisionTime: 50 min
Aim of Experiment: To observe the liquid junction potential and EMF decay when electrolytes mix directly.

Theoretical Foundations

When two electrolytes meet without a salt bridge, ions diffuse across the boundary at different speeds (mobilities), creating a liquid junction potential that adds to the measured EMF. Mixing also slowly destroys the concentration difference, so the EMF decays with time.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Zn and Cu strips
  • U-tube or two beakers joined by a narrow tube
  • Digital voltmeter
  • Connecting wires
  • Stopwatch

Chemical Reagents

  • ZnSO4 (1.0 M)
  • CuSO4 (1.0 M)
  • KNO3 (salt bridge, for comparison)

Step-by-Step Practical Procedure

  1. Fill one arm of the U-tube with ZnSO4 and the other with CuSO4, with Zn and Cu electrodes.
  2. Measure the EMF immediately and then every 2 minutes for 20 minutes.
  3. Note the colour change at the boundary as blue Cu2+ diffuses.
  4. Insert a salt bridge instead of direct contact and compare the stable reading.

Observations & Expected Results

Initial reading differs slightly from 1.10 V (junction potential contribution); it drifts downward as the blue boundary spreads. With a salt bridge the reading is stable.

Worked Stoichiometric Calculations

Problem: A cell reads 1.13 V with direct liquid contact but 1.10 V with a KNO3 salt bridge. Estimate the junction potential.

Working: Ejunction ~ 1.13 - 1.10 = 0.03 V (30 mV), the extra potential from unequal ion diffusion at the direct boundary.

Safety Precautions & Hazard Control

  • Handle the U-tube carefully to keep the boundary sharp initially.
  • Wear gloves with CuSO4.
  • Switch off the power supply before changing any connections.

Waste Disposal Protocol

Collect mixed solutions in the heavy-metal waste container.

Viva Voce Oral Defense Questions & Answers

Q: Why do K+ and NO3- minimise junction potentials?

A: Their ionic mobilities are almost equal, so no significant charge separation develops at the boundary.

Q: Why does the EMF decay when solutions mix?

A: Mixing equalises the ion concentrations, removing the chemical driving force of the cell reaction.