Purification Strategy: The Unknown Mixture Challenge
Design and execute a full purification strategy for an unknown three-component mixture — the capstone.
Theoretical Foundations
Real purification is strategic: identify components (mp, TLC, solubility tests), then order the methods — acid–base extraction for ionisables, distillation/sublimation for volatiles, recrystallisation for the rest, chromatography as backup. Students plan on paper, defend the plan, then execute: the whole batch-11 toolkit deployed as one campaign.
Required Apparatus & Chemicals
Laboratory Apparatus
- Full purification glassware suite
- TLC kit
- Melting-point apparatus
- Balance
Chemical Reagents
- Unknown mixture (instructor-composed, e.g. benzoic acid + naphthalene + p-nitroaniline)
- Extraction solvents, acids, bases
- Recrystallisation solvents
Step-by-Step Practical Procedure
- Analyse: TLC, mp, solubility in NaHCO₃/HCl/ether — identify the components.
- Write the separation flowchart with a justification for each step's order.
- Execute: extraction → isolation → recrystallisation/sublimation of each.
- Characterise each product (mp, TLC single spot); report recoveries and a self-critique.
Observations & Expected Results
Successful campaigns return three characterised solids with sharp mp and clean TLCs; the self-critique (what lost yield, what you'd reorder) is graded as highly as the products.
Worked Stoichiometric Calculations
Problem: Your plan recovered 75%, 80%, 70% of components A, B, C from 1.0 g each. What total pure mass did you obtain, and which step would you improve first?
Working: Total = 0.75 + 0.80 + 0.70 = 2.25 g of 3.0 g (75% overall). Improve the 70% step first — the lowest-yield stage dominates the overall recovery, the purification analogue of the rate-determining step.
Safety Precautions & Hazard Control
- Full PPE; instructor approves the plan before execution.
- Unknown hazards: treat all fractions as harmful until identified.
- Waste-segregate every stream and label it.
Waste Disposal Protocol
Segregated per stream: halogenated, non-halogenated organic, aqueous acid/base, solids.
Viva Voce Oral Defense Questions & Answers
Q: Why analyse before separating?
A: Method choice depends on functional groups and volatility — separating blind wastes the sample on wrong methods.
Q: Your plan put extraction before recrystallisation — defend the order.
A: Extraction handles gram-scale crude splits cheaply; recrystallisation polishes small, pre-enriched fractions — coarse-to-fine ordering minimises total loss.