Desiccator Use: Keeping Dry Things Dry
Learn correct desiccator technique: cooling and storing moisture-sensitive samples.
Theoretical Foundations
A desiccator holds samples over a desiccant (silica gel, CaCl₂) at ~0% humidity: hot crucibles cool without adsorbing atmospheric water (which would corrupt gravimetric weighings), and dry products stay dry. The greased lid seal, the colour-indicating silica (blue → pink when spent), and the venting technique on opening are the craft details.
Required Apparatus & Chemicals
Laboratory Apparatus
- Desiccator with indicating silica gel
- Crucibles
- Tongs
- Balance
Chemical Reagents
- Indicating silica gel (50 g)
- Hygroscopic sample (e.g. dried MgSO4, 5 g)
- Vacuum grease (for the desiccator lid)
Step-by-Step Practical Procedure
- Heat a crucible; transfer it to the desiccator with tongs.
- Seal with the greased lid using the sliding technique.
- Cool 20 min; weigh; compare with air-cooled weighing.
- Check the silica gel colour; regenerate a spent portion in the oven.
Observations & Expected Results
Desiccator-cooled crucible weighs stable; air-cooled gains milligrams of adsorbed water in minutes. Pink silica → blue after oven regeneration.
Worked Stoichiometric Calculations
Problem: A crucible weighed 25.3421 g from the desiccator and 25.3456 g after 5 min in air. What mass of water adsorbed, and what error would that cause in a 1.0000 g gravimetric precipitate?
Working: Adsorbed = 3.5 mg. On a 1.0000 g precipitate that's a 0.35% error — ten times a typical analytical tolerance: desiccator discipline is quantitative, not fussy.
Safety Precautions & Hazard Control
- Slide the lid, don't lift — pressure differential can spray contents.
- Hot crucibles: tongs always.
- Regenerate silica in a ventilated oven.
Waste Disposal Protocol
None significant.
Viva Voce Oral Defense Questions & Answers
Q: Why slide the lid instead of lifting it?
A: Cooling air contracts, gripping the lid; sliding breaks the seal laterally without the pop that can scatter the sample.
Q: Blue to pink silica — what happened chemically?
A: Cobalt chloride indicator hydrated: [CoCl₄]²⁻ (blue) → [Co(H₂O)₆]²⁺ (pink) — the desiccant is spent and needs oven regeneration.