Drying Ethanol: Molecular Sieves vs Chemical Drying
Compare molecular sieves (3 Å) with CaO for drying ethanol, assayed by density.
Theoretical Foundations
3 Å molecular sieves trap water (kinetic diameter 2.6 Å) in their pores while excluding ethanol (4.4 Å) — physical, regenerable drying. CaO reacts chemically (CaO + H₂O → Ca(OH)₂) but can also react with ethanol slowly. Density tracks progress: wet ethanol is denser than dry (0.789 g/mL). Sieves are the modern standard for anhydrous solvents.
Required Apparatus & Chemicals
Laboratory Apparatus
- Conical flasks
- Density: pycnometer or hydrometer
- Balance
- Stopwatch
Chemical Reagents
- 95% ethanol (2 × 50 mL)
- 3 Å molecular sieves (activated, 10 g)
- Quicklime CaO (10 g)
Step-by-Step Practical Procedure
- Measure initial density of the 95% ethanol.
- Treat one portion with activated sieves, one with CaO; leave 1 h with occasional swirling.
- Re-measure densities; compute approximate water content from density tables.
- Compare effectiveness and convenience.
Observations & Expected Results
Sieves: density falls toward 0.789, water <0.5%. CaO: similar drying but the ethanol may pick up a slight odour; sieves are cleaner and reusable.
Worked Stoichiometric Calculations
Problem: Initial density 0.804 g/mL (≈95.6% w/w ethanol); after sieves 0.791 g/mL. Estimate the water removed from 50 mL.
Working: Density tables: 0.804 → 4.4% water; 0.791 → ~0.8% water. 50 mL ≈ 40 g: water removed ≈ 40 × (0.044 − 0.008) ≈ 1.44 g — sieves stripped ~80% of the water in one treatment.
Safety Precautions & Hazard Control
- CaO is caustic — gloves, goggles.
- Activate sieves at ~250 °C before use or they're useless.
- Ethanol flammable.
Waste Disposal Protocol
CaO residue (alkaline) neutralised to aqueous waste; sieves regenerated by heating.
Viva Voce Oral Defense Questions & Answers
Q: Why 3 Å sieves specifically for ethanol?
A: Pore size admits water (2.6 Å) but excludes ethanol (4.4 Å) — molecular sieving by size, the clue is in the name.
Q: How do you know sieves are activated?
A: They're heated to ~250 °C to drive off adsorbed water; cool inactive sieves add water instead of removing it — a classic self-inflicted failure.