Countercurrent Extraction Principle: The Craig Demonstration

Model countercurrent distribution with a Craig-tube series (or paper simulation) to see how many stages separate close-K compounds.

Level: UniversitySafety: Needs supervisionTime: 75 min
Aim of Experiment: Model countercurrent distribution with a Craig-tube series (or paper simulation) to see how many stages separate close-K compounds.

Theoretical Foundations

Countercurrent distribution repeats partition: the upper phase moves one tube forward each stage while the lower stays, so compounds with slightly different K values walk apart into separate tubes — the conceptual ancestor of chromatography. A 10-stage hand Craig series (or spreadsheet) with two dyes of K = 0.8 and 1.2 shows bands resolving: plates, again, but in extraction form.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Test tubes (12) or spreadsheet
  • Two dyes with close K values
  • Separating funnel (to measure K first)
  • Ruler

Chemical Reagents

  • Two food dyes (red, blue)
  • Distilled water (100 mL)
  • n-Butanol (100 mL)

Step-by-Step Practical Procedure

  1. Measure K for each dye between water and butanol.
  2. Perform (or simulate) 10 Craig stages, tracking each dye's tube distribution.
  3. Plot amount per tube for both dyes after 5 and 10 stages.
  4. Decide how many stages resolve them and relate to chromatography plates.

Observations & Expected Results

After 5 stages the bands overlap; after 10 they separate into distinct maxima — resolution grows with √n, the plate logic made visible.

Worked Stoichiometric Calculations

Problem: Dye A (K=0.8) peaks at tube 4, dye B (K=1.2) at tube 6 after 10 stages. If each stage moves a fraction p = K/(1+K) of solute forward, verify dye B's peak position.

Working: p_B = 1.2/2.2 ≈ 0.545; expected peak ≈ n·p = 10 × 0.545 ≈ 5.5 → tube 5–6. ✓. The binomial walk predicts the band positions — chromatography theory in its original extraction clothing.

Safety Precautions & Hazard Control

  • Butanol is flammable and irritating - fume hood.
  • Label tubes meticulously; one mis-tracked tube ruins the series.
  • Wear goggles when shaking the funnel.

Waste Disposal Protocol

Dye solutions to aqueous/organic waste as appropriate.

Viva Voce Oral Defense Questions & Answers

Q: What is the link between Craig stages and chromatography plates?

A: Identical mathematics: repeated equilibration with phase movement — a column is just thousands of Craig tubes in series.

Q: Why do close-K compounds need many stages?

A: Their per-stage movement differs little, so many repetitions are needed to accumulate a visible separation — resolution scales with √n.

← Back to Experiments Directory