CHEMVEN

Partition Coefficient: Iodine Between Water and CCl₄ (or Heptane)

Measure the distribution coefficient of iodine between water and an organic solvent by titration.

Level: UniversitySafety: Needs supervisionTime: 75 min
Aim of Experiment: Measure the distribution coefficient of iodine between water and an organic solvent by titration.

Theoretical Foundations

The Nernst distribution law: at equilibrium, K = C_org/C_aq is constant at fixed temperature. Shaking aqueous iodine with the organic solvent, separating, and titrating each layer with thiosulfate gives both concentrations and hence K — the number that predicts every extraction in the course (see org-pur-058's calculation).

Required Apparatus & Chemicals

Laboratory Apparatus

  • Separating funnels
  • Burette
  • Conical flasks
  • Retort stand and clamps

Chemical Reagents

  • Iodine in KI solution (~0.05 M, 50 mL)
  • Tetrachloromethane or heptane (50 mL)
  • 0.02 M sodium thiosulfate
  • Starch indicator

Step-by-Step Practical Procedure

  1. Shake 50 mL iodine solution with 50 mL organic solvent 5 min; let layers separate fully.
  2. Run off each layer; titrate 10 mL aliquots with thiosulfate (starch near the end).
  3. Calculate [I₂] in each layer from the titres.
  4. Compute K = C_org/C_aq; repeat at a second temperature if time allows.

Observations & Expected Results

Organic layer deeply coloured (violet in heptane), aqueous pale; K typically 80–120 for CCl₄/water — iodine overwhelmingly prefers the organic phase.

Worked Stoichiometric Calculations

Problem: 10 mL organic layer needed 24.0 mL of 0.020 M thiosulfate; 10 mL aqueous needed 3.0 mL. I₂ + 2S₂O₃²⁻ → 2I⁻ + S₄O₆²⁻. Calculate K.

Working: n(S₂O₃) org = 0.020 × 0.024 = 4.8×10⁻⁴ mol → n(I₂) = 2.4×10⁻⁴ in 10 mL → 0.024 M. Aqueous: 0.020 × 0.003 = 6×10⁻⁵ → I₂ = 3×10⁻⁵ in 10 mL → 0.0030 M. K = 0.024/0.0030 = 8.0. (Lower than the true ~85 because I₃⁻ in the KI solution complicates it — a fine discussion point about the law's assumptions.)

Safety Precautions & Hazard Control

  • CCl₄ is toxic — heptane preferred; fume hood either way.
  • Iodine stains; thiosulfate spills cleaned promptly.
  • Vent funnels.

Waste Disposal Protocol

Organic layer to halogenated (or non-halogenated) waste as appropriate; titrated solutions to aqueous waste.

Viva Voce Oral Defense Questions & Answers

Q: Why does added KI lower the measured K?

A: I₂ + I⁻ ⇌ I₃⁻ keeps iodine aqueous as triiodide, which doesn't extract — the law applies to the same molecular species in both phases.

Q: How does K connect to the 'many small extractions' rule?

A: Fraction remaining = [Vaq/(Vaq+K·Vorg)]ⁿ: large K means each portion strips nearly everything, and the exponent n is why splitting the solvent wins.

← Back to Experiments Directory