Naphthalene Purification by Steam Distillation
Purify crude naphthalene by steam distillation, leaving tarry impurities behind.
Theoretical Foundations
Naphthalene (mp 80 °C) has enough vapour pressure near 100 °C to co-distil with steam, while tarry, polymeric impurities are non-volatile and stay in the flask. White crystals deposit in the condenser and receiver — a visually striking purification of a dark crude into snow-white product without any organic solvent.
Required Apparatus & Chemicals
Laboratory Apparatus
- Steam distillation set-up
- Buchner funnel
- Melting-point apparatus
- Filter papers
Chemical Reagents
- Crude naphthalene, dark (10 g)
- Water
- Activated charcoal (optional, for dark distillate)
Step-by-Step Practical Procedure
- Steam-distil the crude naphthalene.
- Collect the white crystalline distillate; continue until no more solid appears.
- Filter, press dry between papers, weigh, and take mp.
- Compare colour and mp with the crude.
Observations & Expected Results
Snow-white plates from a brown-black crude; mp 80–81 °C sharp. Typical recovery 60–75%.
Worked Stoichiometric Calculations
Problem: 10.0 g crude gave 6.8 g white naphthalene (mp 80 °C). The flask residue weighed 2.5 g. What percentage is unaccounted for, and what is it?
Working: Accounted: 9.3 g; missing 0.7 g = 7%. Naphthalene vapour lost through the receiver vent and crystals stuck in the condenser — volatile products always lose a little to the apparatus.
Safety Precautions & Hazard Control
- Naphthalene vapour is harmful — fume hood.
- Do not let the condenser block with crystals; keep water flowing.
- Steam burns.
Waste Disposal Protocol
Tarry residue to organic waste.
Viva Voce Oral Defense Questions & Answers
Q: Why does steam distillation beat recrystallisation for tarry crude naphthalene?
A: Tars co-dissolve in recrystallisation solvents and co-precipitate; steam distillation leaves every non-volatile impurity in the pot — a volatility filter, not a solubility one.
Q: Why keep the condenser water flowing fast?
A: Naphthalene solidifies on cool surfaces; a warm-blocked condenser would choke the apparatus and pressurise it.