CHEMVEN

Clausius–Clapeyron in Action: bp vs Pressure for Ethyl Benzoate

Measure the boiling point of ethyl benzoate at several pressures and verify the Clausius–Clapeyron equation.

Level: UniversitySafety: Advanced lab onlyTime: 2 h
Aim of Experiment: Measure the boiling point of ethyl benzoate at several pressures and verify the Clausius–Clapeyron equation.

Theoretical Foundations

ln(P2/P1) = −ΔHvap/R · (1/T2 − 1/T1): boiling temperature falls logarithmically with pressure. Distilling ethyl benzoate (normal bp 213 °C) at four controlled pressures (e.g. 100, 50, 25, 12 mmHg) gives a ln P vs 1/T plot whose slope is −ΔHvap/R — a physical-chemistry measurement made with preparative glassware.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Vacuum distillation set-up with fine vacuum control
  • Manometer
  • Heating mantle
  • Claisen head

Chemical Reagents

  • Ethyl benzoate (60 mL)
  • Anti-bump granules
  • Silicone grease (for joints)

Step-by-Step Practical Procedure

  1. At each of four pressures, establish steady distillation and record the head temperature.
  2. Tabulate P (mmHg) and T (K); compute ln P and 1/T.
  3. Plot ln P vs 1/T; determine the slope.
  4. Calculate ΔHvap and compare with the literature (~55 kJ/mol).

Observations & Expected Results

Typical: 100 mmHg → ~150 °C; 50 → ~130 °C; 25 → ~112 °C; 12 → ~95 °C. Plot linear with R² > 0.99 when done carefully.

Worked Stoichiometric Calculations

Problem: Data: (100 mmHg, 423 K), (25 mmHg, 385 K). Estimate ΔHvap from these two points.

Working: ln(100/25) = 1.386 = (ΔHvap/8.314)(1/385 − 1/423) = (ΔHvap/8.314)(0.0002333). ΔHvap = 1.386 × 8.314/0.0002333 ≈ 49,400 J/mol ≈ 49 kJ/mol — within ~10% of literature, good for two-point bench data.

Safety Precautions & Hazard Control

  • Control vacuum changes slowly — sudden jumps cause bumping.
  • Implosion screen.
  • Release vacuum before cooling.

Waste Disposal Protocol

Distillate retained; residue to organic waste.

Viva Voce Oral Defense Questions & Answers

Q: What does the slope of ln P vs 1/T physically mean?

A: −ΔHvap/R: the energy barrier to vaporisation — steeper slope means bp is more pressure-sensitive.

Q: Why is the plot linear only over modest ranges?

A: ΔHvap itself varies with temperature; over wide ranges the line curves, so the two-point estimate is approximate.

← Back to Experiments Directory