CHEMVEN

Vacuum Distillation of Nitrobenzene: A Heat-Sensitive Liquid

Purify nitrobenzene (bp 211 °C) by vacuum distillation at ~100 °C, avoiding thermal hazards.

Level: UniversitySafety: Advanced lab onlyTime: 90 min
Aim of Experiment: Purify nitrobenzene (bp 211 °C) by vacuum distillation at ~100 °C, avoiding thermal hazards.

Theoretical Foundations

Nitrobenzene's high normal bp makes atmospheric distillation energy-intensive and risky (nitroaromatics + heat). At ~15 mmHg it boils near 100 °C — safely below decomposition — demonstrating vacuum distillation's role with energetic or sensitive compounds. The pale-yellow distillate vs dark residue shows the purification directly.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Vacuum distillation set-up (flask, Claisen head, condenser)
  • Capillary air bleed
  • Vacuum adapter + receiver
  • Safety screen

Chemical Reagents

  • Nitrobenzene, technical (40 mL)
  • Anti-bump granules
  • Silicone grease (for joints)

Step-by-Step Practical Procedure

  1. Leak-test the evacuated apparatus before heating.
  2. Distil at 10–20 mmHg, recording bp vs pressure.
  3. Collect the pale-yellow fraction; leave dark residue.
  4. Compare odour/colour of distillate vs starting material.

Observations & Expected Results

Distils ~99–105 °C at ~15 mmHg; typical recovery 80%. Residue dark with tarry impurities.

Worked Stoichiometric Calculations

Problem: Nitrobenzene boiled at 102 °C at 14 mmHg. If the vacuum slipped to 40 mmHg mid-run, would the observed bp rise or fall, and why?

Working: Rise: higher external pressure needs a higher temperature for the vapour pressure to match it — the operator would see the head temperature climb, signalling the leak before product quality suffers.

Safety Precautions & Hazard Control

  • Nitrobenzene is toxic by skin absorption — gloves, fume hood.
  • Implosion screen mandatory.
  • Release vacuum before cooling.

Waste Disposal Protocol

Nitrobenzene residues to labelled organic waste — never down the sink.

Viva Voce Oral Defense Questions & Answers

Q: Why is vacuum distillation preferred for nitro compounds?

A: Heat + nitroaromatics risks exothermic decomposition; vacuum keeps temperatures ~100 °C lower, inside the safe envelope.

Q: What does a climbing head temperature under steady heating indicate?

A: A vacuum leak (pressure rising) or the pot running dry of the volatile component — both demand attention, not more heat.