Fractional Distillation of a Three-Component Mixture
Resolve acetone (56 °C), water (100 °C), and toluene (111 °C) — testing whether the column can handle two gaps, one small.
Theoretical Foundations
Three components need two separations in one run: the easy acetone gap then the hard water–toluene gap (11 °C). The column must deliver enough plates for the tightest pair; the temperature trace shows two plateaus separated by a long climb. This is the bench analogue of refinery multi-cut fractionation.
Required Apparatus & Chemicals
Laboratory Apparatus
- Packed fractional distillation set-up
- Thermometer
- Three receivers
- Retort stand and clamps
Chemical Reagents
- Acetone (25 mL)
- Distilled water (25 mL)
- Toluene (25 mL)
- Boiling stones
Step-by-Step Practical Procedure
- Fractionally distil slowly with good reflux.
- Collect acetone (55–58 °C), intermediate, and toluene (109–112 °C) cuts.
- Note where the water goes — and the cloudy water–toluene azeotrope behaviour.
- Assess each cut by bp range and refractive index.
Observations & Expected Results
Clean acetone plateau; then a prolonged 85–110 °C climb (water co-distilling, partly as heterogeneous azeotrope with toluene at ~85 °C); toluene plateau last. Water–toluene never splits cleanly — a built-in lesson.
Worked Stoichiometric Calculations
Problem: 25 mL of each component were charged. Recovered: 20 mL acetone cut, 18 mL toluene cut, 8 mL intermediate, 15 mL water-rich residue. Calculate the overall mass accountability.
Working: In: 75 mL. Out: 20+18+8+15 = 61 mL → 81% accounted. Missing 14 mL: column hold-up, forerun, evaporation, and water–toluene azeotrope losses — multi-cut runs always lose more to the apparatus.
Safety Precautions & Hazard Control
- Flammables — mantle only, fume hood.
- Long run: check cooling water periodically.
- Never distil to dryness.
Waste Disposal Protocol
Off-cuts to organic waste; water cut to aqueous waste.
Viva Voce Oral Defense Questions & Answers
Q: Why did water and toluene refuse to separate cleanly?
A: They form a heterogeneous azeotrope (bp ~85 °C) — immiscible liquids co-distil at a fixed ratio, defeating the column.
Q: What does the long temperature climb between plateaus represent?
A: The column working through the water-rich transition: many plates consumed on a separation the bp gap says is marginal.