Fractional Distillation: Acetone–Toluene with a Vigreux Column
Separate acetone (56 °C) from toluene (111 °C) using a Vigreux column and compare with simple distillation.
Theoretical Foundations
A fractionating column provides many successive vaporisation–condensation cycles (theoretical plates): vapour condenses on the glass indentations, re-evaporates enriched in the volatile component, and climbs purer at each stage. With a 55 °C bp gap, a Vigreux column gives a sharp split — acetone plateau, rapid rise, toluene plateau — where simple distillation would smear the transition.
Required Apparatus & Chemicals
Laboratory Apparatus
- Round-bottom flask
- Vigreux column
- Still head + thermometer
- Liebig condenser
- Heating mantle
- Two receiving flasks
Chemical Reagents
- Acetone (30 mL)
- Toluene (30 mL)
- Boiling stones
Step-by-Step Practical Procedure
- Assemble with the Vigreux column between flask and still head; lag the column with glass wool.
- Heat so reflux is visible in the column (about 1 drop reflux per drop collected).
- Record head temperature per 5 mL; collect the 55–58 °C and 109–112 °C fractions separately.
- Compare the sharpness of the temperature jump with a simple-distillation run.
Observations & Expected Results
Long 56 °C plateau, steep jump, long 111 °C plateau. Typical: ~25 mL acetone fraction (>95% pure) and ~25 mL toluene fraction.
Worked Stoichiometric Calculations
Problem: The temperature jumped from 58 °C to 108 °C within 3 mL of distillate. In a simple distillation of the same mixture the transition spanned 15 mL. What does the 5-fold sharpening mean in plate terms?
Working: The column multiplies the single vaporisation of simple distillation into many equilibrations: the 3 mL transition implies roughly 5+ theoretical plates vs ~1 for simple distillation — each plate re-enriches the vapour, compressing the intermediate-composition cut.
Safety Precautions & Hazard Control
- Both solvents flammable — heating mantle only, fume hood.
- Maintain steady reflux; flooding the column ruins separation.
- Never distil to dryness.
Waste Disposal Protocol
Intermediate mixed cut to organic waste; pure fractions labelled and kept.
Viva Voce Oral Defense Questions & Answers
Q: What is a theoretical plate?
A: One ideal vaporisation–condensation equilibrium stage; a column's plate count measures its separating power.
Q: Why lag (insulate) the column?
A: Heat loss causes excessive condensation low in the column, collapsing the temperature gradient and losing plates.