CHEMVEN

Fractional Distillation: Acetone–Toluene with a Vigreux Column

Separate acetone (56 °C) from toluene (111 °C) using a Vigreux column and compare with simple distillation.

Level: UniversitySafety: Needs supervisionTime: 90 min
Aim of Experiment: Separate acetone (56 °C) from toluene (111 °C) using a Vigreux column and compare with simple distillation.

Theoretical Foundations

A fractionating column provides many successive vaporisation–condensation cycles (theoretical plates): vapour condenses on the glass indentations, re-evaporates enriched in the volatile component, and climbs purer at each stage. With a 55 °C bp gap, a Vigreux column gives a sharp split — acetone plateau, rapid rise, toluene plateau — where simple distillation would smear the transition.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Round-bottom flask
  • Vigreux column
  • Still head + thermometer
  • Liebig condenser
  • Heating mantle
  • Two receiving flasks

Chemical Reagents

  • Acetone (30 mL)
  • Toluene (30 mL)
  • Boiling stones

Step-by-Step Practical Procedure

  1. Assemble with the Vigreux column between flask and still head; lag the column with glass wool.
  2. Heat so reflux is visible in the column (about 1 drop reflux per drop collected).
  3. Record head temperature per 5 mL; collect the 55–58 °C and 109–112 °C fractions separately.
  4. Compare the sharpness of the temperature jump with a simple-distillation run.

Observations & Expected Results

Long 56 °C plateau, steep jump, long 111 °C plateau. Typical: ~25 mL acetone fraction (>95% pure) and ~25 mL toluene fraction.

Worked Stoichiometric Calculations

Problem: The temperature jumped from 58 °C to 108 °C within 3 mL of distillate. In a simple distillation of the same mixture the transition spanned 15 mL. What does the 5-fold sharpening mean in plate terms?

Working: The column multiplies the single vaporisation of simple distillation into many equilibrations: the 3 mL transition implies roughly 5+ theoretical plates vs ~1 for simple distillation — each plate re-enriches the vapour, compressing the intermediate-composition cut.

Safety Precautions & Hazard Control

  • Both solvents flammable — heating mantle only, fume hood.
  • Maintain steady reflux; flooding the column ruins separation.
  • Never distil to dryness.

Waste Disposal Protocol

Intermediate mixed cut to organic waste; pure fractions labelled and kept.

Viva Voce Oral Defense Questions & Answers

Q: What is a theoretical plate?

A: One ideal vaporisation–condensation equilibrium stage; a column's plate count measures its separating power.

Q: Why lag (insulate) the column?

A: Heat loss causes excessive condensation low in the column, collapsing the temperature gradient and losing plates.

← Back to Experiments Directory