Solvent Recovery: Distilling Ethyl Acetate from a Reaction Mixture
Recover ethyl acetate solvent from a mock reaction residue by distillation — a green-chemistry routine.
Theoretical Foundations
Distillation is the workhorse of solvent recycling: the volatile solvent (ethyl acetate, bp 77 °C) vaporises away from non-volatile residues (salts, tars, drying agent). A short, steady distillation with the head temperature pinned at the solvent bp gives recovered solvent pure enough for reuse in most teaching-lab steps, cutting waste and cost.
Required Apparatus & Chemicals
Laboratory Apparatus
- Distillation set-up
- Heating mantle
- Thermometer
- Receiving flask
Chemical Reagents
- Ethyl acetate (55 mL)
- Non-volatile residue (mock: sodium benzoate, 5 g)
- Boiling stones
Step-by-Step Practical Procedure
- Assemble the apparatus; add boiling stones.
- Distil steadily, collecting the 76–78 °C fraction.
- Stop with ~10 mL residue remaining; weigh the recovered solvent.
- Check purity by bp range and, if available, a TLC spot vs fresh solvent.
Observations & Expected Results
Constant 77 °C head temperature; recovered solvent colourless vs yellow-brown residue. Typical recovery 80–85%.
Worked Stoichiometric Calculations
Problem: 60 mL of mixture (density ~0.90 g/mL, ~90% ethyl acetate by mass) gave 41 g of recovered solvent. Calculate the recovery efficiency.
Working: Ethyl acetate present ≈ 60 × 0.90 × 0.90 = 48.6 g. Recovery = 41/48.6 × 100 ≈ 84%. The rest stays in the residue, the forerun, and apparatus hold-up.
Safety Precautions & Hazard Control
- Ethyl acetate is flammable — controlled heating.
- Do not distil to dryness; residues may contain peroxides in old solvents.
- Cool before dismantling.
Waste Disposal Protocol
Non-volatile residue to organic waste; recovered solvent labelled and reused.
Viva Voce Oral Defense Questions & Answers
Q: Why is solvent recovery green chemistry?
A: It cuts both purchase and disposal volumes — waste prevention beats waste treatment.
Q: When would recovered solvent NOT be reused?
A: For analytical or water-sensitive work where trace impurities matter; then it is redistilled or used for cleaning only.