Simple Distillation: Separating Acetone from Water
Separate acetone (bp 56 °C) from water by simple distillation and check the distillate purity by boiling range.
Theoretical Foundations
Simple distillation works when boiling points differ by more than ~25 °C: the vapour is enriched in the more volatile component (Raoult's law), and one vaporisation–condensation cycle gives a useful separation for acetone (56 °C) vs water (100 °C). The thermometer at the still head reads the vapour temperature of the distilling component; a constant reading signals a pure fraction.
Required Apparatus & Chemicals
Laboratory Apparatus
- Round-bottom flask (100 mL)
- Still head + thermometer
- Liebig condenser
- Receiving adapter + flask
- Hot plate / heating mantle
Chemical Reagents
- Acetone (25 mL)
- Distilled water (25 mL)
- Boiling stones
Step-by-Step Practical Procedure
- Assemble the distillation with the thermometer bulb level with the condenser side-arm.
- Add the mixture plus boiling stones; heat gently.
- Discard the first 1–2 mL (forerun); record the head temperature every 2 mL collected.
- Collect the fraction boiling 55–58 °C; stop when the temperature rises toward 100 °C or ~10 mL remains.
- Measure the volume and boiling range of the distillate.
Observations & Expected Results
Steady head temperature ~56 °C during the acetone fraction, then a climb toward 100 °C. Typical recovery of acetone 70–80% with a 2–3 °C boiling range.
Worked Stoichiometric Calculations
Problem: 50 mL of 1:1 acetone–water gave 19 mL of distillate (bp 55–57 °C). What is the acetone recovery, and why is it not 100%?
Working: Acetone present = 25 mL; recovery = 19/25 × 100 = 76%. Losses: forerun discarded, acetone left in the residue, vapour held up in the apparatus, and some co-distilled water — one theoretical plate cannot give a perfect split.
Safety Precautions & Hazard Control
- Acetone is highly flammable — no open flames; heating mantle or plate only.
- Never distil to dryness (peroxide/bumping hazard with some solvents).
- Add boiling stones before heating.
Waste Disposal Protocol
Residue (mostly water) to aqueous waste; forerun to organic waste.
Viva Voce Oral Defense Questions & Answers
Q: Why must the thermometer bulb sit at the side-arm level?
A: It must read the vapour temperature entering the condenser; lower reads the boiling liquid (superheated), higher reads cooled vapour — both mislead.
Q: When does simple distillation fail?
A: When bp differ by less than ~25 °C or an azeotrope forms — then fractional distillation or another method is needed.