Recrystallisation of Acetanilide: Water as a Near-Ideal Solvent
Recrystallise impure acetanilide from water and compare crude vs purified melting points.
Theoretical Foundations
An ideal recrystallisation solvent dissolves much solute hot and little cold. Acetanilide fits water well: about 0.5 g per 100 mL dissolves at 20 °C but roughly 5 g per 100 mL near 100 °C, so ~90% crystallises on cooling. Slow cooling grows large, pure plates; impurities remain dissolved or are filtered off hot. Pure acetanilide melts at 113–114 °C.
Required Apparatus & Chemicals
Laboratory Apparatus
- Conical flask (250 mL)
- Hot plate
- Fluted filter paper + funnel
- Buchner funnel
- Melting-point apparatus
- Balance
Chemical Reagents
- Impure acetanilide (5.0 g)
- Distilled water (approx 110 mL)
- Activated charcoal (optional)
- Ice bath
Step-by-Step Practical Procedure
- Record the melting point of the crude acetanilide first.
- Add 5.0 g to a flask with 90 mL water; heat to boiling, adding more water dropwise until fully dissolved.
- If coloured, add a little charcoal, boil 2 min, and hot-filter through fluted paper.
- Cover and cool the filtrate slowly, then chill in ice for 15 min.
- Vacuum-filter, wash with ice-cold water, dry, weigh, and take the melting point.
Observations & Expected Results
White plate-like crystals; typical recovery 70–80% (about 3.5–4.0 g). Crude mp often 105–110 °C broad; pure product 113–114 °C sharp.
Worked Stoichiometric Calculations
Problem: 5.00 g crude acetanilide yielded 3.75 g pure crystals. Calculate recovery. The crude mp was 106–111 °C and the product 113–114 °C — what does the change show?
Working: Recovery = 3.75/5.00 × 100 = 75%. The mp rose and the range narrowed from 5 °C to 1 °C, showing impurities (which depress and broaden the mp) were removed.
Safety Precautions & Hazard Control
- Avoid prolonged boiling — acetanilide hydrolyses slowly in hot water to aniline and acetic acid.
- Never add charcoal to boiling liquid.
- Dry crystals fully before mp: trapped water depresses the reading.
Waste Disposal Protocol
Aqueous filtrate to aqueous waste; charcoal paper to solid waste.
Viva Voce Oral Defense Questions & Answers
Q: Why does an impurity lower and broaden the melting point?
A: It disrupts the crystal lattice, so less thermal energy is needed to collapse it, and melting occurs over a range as composition shifts — the basis of the mixed-melting-point test.
Q: Why wash with ice-cold water, not room-temperature water?
A: Cold water minimises redissolving the product while rinsing mother liquor off the crystal surfaces.