Tetraamminecopper(II) Sulfate (Cuprammonium Complex)
To prepare tetraamminecopper(II) sulfate monohydrate by the action of ammonia on copper sulfate.
Theoretical Foundations
Copper sulfate with excess concentrated ammonia first precipitates Cu(OH)2, which redissolves as the deep blue complex: CuSO4 + 4NH3 + H2O → [Cu(NH3)4]SO4·H2O. Adding ethanol precipitates the dark blue crystals of the complex salt.
Required Apparatus & Chemicals
Laboratory Apparatus
- 250 mL beaker
- Glass rod
- Funnel
- Filter paper
- Weighing balance
- Measuring cylinder
Chemical Reagents
- Copper sulfate pentahydrate, CuSO4·5H2O (24.97 g)
- Concentrated ammonia solution (60 mL)
- Ethanol (80 mL)
- Distilled water (80 mL)
Step-by-Step Practical Procedure
- Dissolve 24.97 g CuSO4·5H2O in 60 mL water.
- Add concentrated ammonia slowly; a pale blue precipitate forms first.
- Continue adding ammonia until the precipitate redissolves to a deep blue solution.
- Filter if turbid.
- Add 80 mL ethanol slowly with stirring; dark blue crystals separate.
- Filter, wash with ethanol, dry between filter papers, and weigh.
Observations & Expected Results
Deep blue-violet crystals; typical yield 21–23 g.
Worked Stoichiometric Calculations
Problem: 24.97 g CuSO4·5H2O (M = 249.68) reacts with excess ammonia. Calculate the theoretical yield of [Cu(NH3)4]SO4·H2O (M = 245.75). If 22.0 g is obtained, find the percentage yield.
Working: Moles CuSO4·5H2O = 24.97/249.68 = 0.100 mol → 0.100 mol complex. Theoretical mass = 0.100 × 245.75 = 24.6 g. Percentage yield = (22.0/24.6) × 100 = 89.4%.
Safety Precautions & Hazard Control
- Use concentrated ammonia in a ventilated area.
- Add ethanol slowly for well-formed crystals.
- The complex loses ammonia on strong heating.
- Copper residues to heavy-metal waste.
Waste Disposal Protocol
Copper/ammonia filtrates go to the heavy-metal inorganic waste container.
Viva Voce Oral Defense Questions & Answers
Q: What is the coordination number and geometry of Cu(II) here?
A: 4 (square planar [Cu(NH3)4]2+), with water/sulfate in the lattice.
Q: Why is the solution deep blue?
A: Strong-field NH3 ligands shift the d–d absorption of Cu(II).
Q: What happens on heating the complex?
A: It loses ammonia: [Cu(NH3)4]SO4 → CuSO4 + 4NH3.