CHEMVEN

Hydrogen from Zinc and Dilute Sulfuric Acid

To prepare hydrogen gas by the action of dilute sulfuric acid on granulated zinc.

Level: UniversitySafety: Needs supervisionTime: 45 min
Aim of Experiment: To prepare hydrogen gas by the action of dilute sulfuric acid on granulated zinc.

Theoretical Foundations

Zinc, being above hydrogen in the reactivity series, displaces hydrogen from dilute acids: Zn + H2SO4(dil) → ZnSO4 + H2↑. The gas is collected over water after flushing out air, since hydrogen–air mixtures are explosive.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conical flask
  • Thistle funnel
  • Delivery tube
  • Pneumatic trough
  • Gas jars
  • Stand with clamp
  • Bunsen burner (for test only)

Chemical Reagents

  • Granulated zinc (6.5 g)
  • Dilute sulfuric acid (80 mL)
  • Water for trough
  • Copper sulfate crystals (catalyst, optional)

Step-by-Step Practical Procedure

  1. Place 6.5 g granulated zinc in a conical flask fitted with thistle funnel and delivery tube.
  2. Add 80 mL dilute sulfuric acid through the funnel.
  3. Allow the first bubbles to escape (flushing out air) for 2 minutes.
  4. Collect 3–4 jars of gas over water.
  5. Test: a burning splint at the mouth gives a pop sound.
  6. Show hydrogen is lighter than air by pouring it upward into an inverted jar.

Observations & Expected Results

Colourless, odourless gas; burns with a pale blue flame and a characteristic pop; typical collection ~2.0 L.

Worked Stoichiometric Calculations

Problem: 6.5 g Zn (M = 65.38) reacts with excess dilute H2SO4. Calculate the theoretical STP volume of H2 evolved.

Working: Moles Zn = 6.5/65.38 = 0.0994 mol ≈ 0.100 mol → 0.100 mol H2. Volume at STP = 0.100 × 22.4 = 2.24 L (2.23 L with exact moles).

Safety Precautions & Hazard Control

  • Flush out all air before collecting; H2–air mixtures explode.
  • Never bring a flame near the generating flask.
  • Add a crystal of CuSO4 to speed up a slow reaction (forms a Zn–Cu couple).
  • Use dilute acid; concentrated H2SO4 gives SO2, not H2.

Waste Disposal Protocol

Zinc sulfate solution is poured into the inorganic aqueous waste container after dilution.

Viva Voce Oral Defense Questions & Answers

Q: Why must air be flushed out before collecting hydrogen?

A: Hydrogen forms an explosive mixture with air.

Q: Why does copper sulfate speed up the reaction?

A: Copper deposits on zinc forming a galvanic couple that accelerates dissolution.

Q: Why is concentrated H2SO4 not used?

A: It is an oxidizing acid and gives SO2 with zinc instead of hydrogen.

← Back to Experiments Directory