Qualitative Analysis of Limestone: Calcium Carbonate
Prove a limestone chip is CaCO₃: carbonate test plus calcium confirmation, with impurity survey.
Theoretical Foundations
Limestone effervesces with dilute HCl (CO₂ → milky limewater). The resulting CaCl₂ solution gives white CaC₂O₄ with ammonium oxalate and a brick-red flame. Iron impurities tint the acid extract yellow (thiocyanate test); Mg²⁺ may appear in dolomitic limestone (titan yellow after Ca removal).
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes
- Mortar and pestle
- Dropper
- Bunsen burner + wire
Chemical Reagents
- Limestone chips
- Dilute HCl (~2 M)
- Limewater
- Ammonium oxalate
- Aqueous NH₃
- KSCN
- Titan yellow
- NaOH
Step-by-Step Practical Procedure
- Powder the limestone; add dilute HCl: effervescence; test gas with limewater (milky).
- Filter the extract; add ammonium oxalate (ammoniacal): white CaC₂O₄.
- Flame-test the extract: brick-red (Ca).
- Test the extract with KSCN: red = Fe impurity.
- Remove Ca as oxalate; test filtrate with titan yellow/NaOH: red = Mg (dolomitic).
Observations & Expected Results
CO₂ confirmed; Ca confirmed twice; impurity survey for Fe/Mg.
Worked Stoichiometric Calculations
Problem: 1.00 g limestone gives 0.44 g CO₂ on acid treatment. % CaCO₃? (illustrative)
Working: CaCO₃ → CO₂: 0.44 g CO₂ = 0.010 mol → 1.00 g CaCO₃ = 100% (illustrative pure sample).
Safety Precautions & Hazard Control
- HCl corrosive — goggles.
- Dust — avoid inhalation when powdering.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Neutralised extracts to sink; oxalate residues to chemical waste.
Viva Voce Oral Defense Questions & Answers
Q: How is limestone distinguished from dolomite here?
A: Dolomite (CaMg(CO₃)₂) gives the Mg titan-yellow test after Ca removal; pure limestone does not.
Q: Why powder the sample?
A: Surface area — coarse chips react too slowly for clean observations.