Qualitative Analysis of Solder: Lead and Tin
Dissolve soft solder and confirm Pb and Sn by their classic tests.
Theoretical Foundations
Solder (Pb–Sn alloy) dissolves in warm dilute HNO₃: Pb → Pb(NO₃)₂; Sn → metastannic acid (H₂SnO₃, white precipitate) — tin's signature insolubility in HNO₃. Pb²⁺ confirmed by yellow PbCrO₄ or white PbSO₄; tin confirmed by dissolving metastannic acid in HCl and reducing HgCl₂ (white→grey) or the cacotheline violet test.
Required Apparatus & Chemicals
Laboratory Apparatus
- Beaker
- Test tubes
- Fume cupboard
- Filter paper + funnel
Chemical Reagents
- Solder pieces
- Dilute HNO₃ (~4 M)
- Concentrated HCl
- K₂CrO₄
- HgCl₂ (~0.05 M)
- Cacotheline
Step-by-Step Practical Procedure
- Warm solder in dilute HNO₃ (fume cupboard): Pb dissolves; white metastannic acid precipitates.
- Filter: filtrate = Pb²⁺; residue = tin as H₂SnO₃.
- Filtrate + K₂CrO₄: yellow PbCrO₄ (Pb confirmed).
- Dissolve residue in conc. HCl; add to HgCl₂: white→grey (Sn²⁺ confirmed).
- Report the alloy components.
Observations & Expected Results
White metastannic acid (Sn); yellow chromate (Pb); HgCl₂ reduction sequence.
Worked Stoichiometric Calculations
Problem: Why does tin give a precipitate with HNO₃ while lead dissolves?
Working: HNO₃ oxidises Sn to insoluble metastannic acid H₂SnO₃; Pb(NO₃)₂ is soluble — a built-in separation.
Safety Precautions & Hazard Control
- Lead toxicity; NO₂ fumes — fume cupboard.
- HgCl₂ toxic — gloves.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Lead/tin/mercury residues segregated to heavy-metal waste.
Viva Voce Oral Defense Questions & Answers
Q: What is metastannic acid?
A: Hydrated tin(IV) oxide, H₂SnO₃ — the white insoluble product of Sn + hot conc. HNO₃.
Q: How is this separation like Group I/II logic?
A: Same principle: exploit a solubility difference (here, nitrate vs oxide) to split two metals.