Analysis in Presence of Interfering Radicals: Putting It Together
Analyse a mixture containing an interfering radical (phosphate) plus Group III/IV cations using the full clean-up scheme.
Theoretical Foundations
The complete interference workflow: (1) preliminary anion tests identify PO₄³⁻/C₂O₄²⁻/F⁻/BO₃³⁻; (2) targeted removal (zirconyl nitrate / ignition / H₂SO₄ fuming); (3) verification of removal (molybdate negative); (4) standard cation scheme. This experiment integrates 083–085 with the group separations.
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes (10)
- Crucible + burner
- Filter papers + funnels
- Fume cupboard
Chemical Reagents
- Unknown (cations + phosphate spike)
- Zirconyl nitrate
- Conc. HNO₃
- Ammonium molybdate
- NH₄Cl
- Aqueous NH₃
- NaOH + H₂O₂ (peroxide separation)
- Standard Group III/IV reagents
Step-by-Step Practical Procedure
- Run preliminary tests: identify the interfering radical (molybdate yellow = phosphate).
- Remove phosphate with zirconyl nitrate in HNO₃; filter; verify removal.
- Run Group III precipitation (NH₄Cl/NH₄OH) on the filtrate.
- Separate Fe/Al/Cr via NaOH/H₂O₂; confirm each.
- Analyse the Group III filtrate for Group IV cations.
- Report cations with evidence and note the interference handled.
Observations & Expected Results
Clean group separations only after the interference is removed — the control without removal fails.
Worked Stoichiometric Calculations
Problem: Why verify removal before proceeding?
Working: Residual phosphate re-precipitates Group III metals downstream; a negative molybdate test is the gate check.
Safety Precautions & Hazard Control
- Full scheme hazards: acids, H₂S if used, chromate — fume cupboard, goggles, gloves.
- Wear safety goggles and a lab coat throughout the experiment.
- Tie back long hair and secure loose clothing before starting.
Waste Disposal Protocol
Segregate phosphate/zirconium, chromate and heavy-metal wastes.
Viva Voce Oral Defense Questions & Answers
Q: What is the most common exam trap here?
A: Forgetting that phosphate must be removed before Group III — the scheme silently fails otherwise.
Q: How do you choose the removal method?
A: Match it to the radical: ignition for oxalate, zirconyl for phosphate, fuming for fluoride/borate.