Removal of Fluoride and Borate: Sulphuric Acid Fuming
Expel interfering fluoride and borate by fuming with concentrated H₂SO₄.
Theoretical Foundations
Fluoride complexes Al³⁺/Fe³⁺ (as [AlF₆]³⁻) blocking Group III; borate buffers and complexes. Fuming with conc. H₂SO₄ expels HF (SiF₄ with glass) and H₃BO₃ as volatile species: CaF₂ + H₂SO₄ → 2HF↑ + CaSO₄. After fuming to dryness and HCl extraction, the metals are free for analysis.
Required Apparatus & Chemicals
Laboratory Apparatus
- Fume cupboard
- Porcelain dish
- Glass rod
- Test tubes
Chemical Reagents
- Mixture spiked with NaF and borax
- Concentrated H₂SO₄
- Dilute HCl (~2 M)
- Ammonium molybdate (control tests)
Step-by-Step Practical Procedure
- Confirm fluoride (etch test, small scale) and borate (turmeric) in the spiked mixture.
- Add conc. H₂SO₄ in the fume cupboard; heat to fuming; evaporate almost to dryness.
- Cool; extract with dilute HCl; filter.
- Show Al³⁺ now precipitates cleanly with NH₃ (previously complexed by F⁻).
- Note: repeat fuming if the etch test is still positive.
Observations & Expected Results
Interference tests positive before, negative after fuming.
Worked Stoichiometric Calculations
Problem: [AlF₆]³⁻ has Kf ~10²⁰. Why does this block the Al(OH)₃ test?
Working: The complex locks [Al³⁺] so low that Q < Ksp(Al(OH)₃) — no hydroxide can precipitate until F⁻ is expelled.
Safety Precautions & Hazard Control
- HF evolution — fume cupboard, face shield, minimal scale.
- Conc. H₂SO₄ — severe burns hazard.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Fumed residues neutralised with lime; fluoride waste segregated.
Viva Voce Oral Defense Questions & Answers
Q: Why fume 'almost to dryness'?
A: To drive off the last HF/H₃BO₃; residual H₂SO₄ is then diluted out in the HCl extraction.
Q: What glassware caution applies?
A: HF etches glass — use porcelain/platinum for the fuming step.