Nitrate Test: The Brown Ring
Detect NO₃⁻ by the brown-ring test with FeSO₄ and concentrated H₂SO₄.
Theoretical Foundations
Layering conc. H₂SO₄ under a mixture of nitrate + FeSO₄ gives a brown ring of [Fe(H₂O)₅(NO)]²⁺ at the interface: NO₃⁻ + 3Fe²⁺ + 4H⁺ → NO + 3Fe³⁺ + 2H₂O, then Fe²⁺ + NO → [Fe(NO)]²⁺ (brown). Nitrite also gives colour but is removed beforehand with urea/sulphamic acid.
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes
- Dropper
- Test-tube rack
- Test-tube holder
Chemical Reagents
- Potassium nitrate (~0.1 M)
- Fresh iron(II) sulphate (~0.2 M)
- Concentrated H₂SO₄
- Urea (nitrite removal, if needed)
Step-by-Step Practical Procedure
- Mix equal volumes of nitrate solution and fresh FeSO₄.
- Tilt the tube; pour conc. H₂SO₄ slowly down the side to form a lower layer.
- A brown ring forms at the junction within minutes.
- Run a nitrite control (brown throughout, not a ring) and a blank.
Observations & Expected Results
Sharp brown ring at the acid interface = nitrate.
Worked Stoichiometric Calculations
Problem: Why must FeSO₄ be fresh?
Working: Fe²⁺ air-oxidises to Fe³⁺, which cannot reduce NO₃⁻ to NO — stale reagent gives false negatives.
Safety Precautions & Hazard Control
- Conc. H₂SO₄ — severe burns hazard; pour slowly, goggles, lab coat.
- Nitrite interference — destroy with urea first if present.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Acidic iron waste neutralised, then to chemical waste.
Viva Voce Oral Defense Questions & Answers
Q: What is the brown ring chemically?
A: [Fe(H₂O)₅(NO)]²⁺ — an Fe(I)–NO⁺ nitrosyl complex.
Q: Why layer instead of mixing?
A: The ring needs the concentration gradient at the interface; mixing disperses the colour.